Service diagnosis
34
Domestic air conditioner
10.3 Error Codes and Description indoor display
Code indication
fault description
Reference
Page
Indoor displaying panel code
indication
Outdoor
(LED1
flash
times)
Other
display
Only For 498 and
498A display
(Red/Green Time Run
,)
Indoor and
Outdoor
E7
15
Communication fault between
indoor and outdoor units
Page.42
Indoor
Malfunction
E1
--
Room temperature sensor failure Page.31
E2
--
Heat-exchange sensor failure
Page.31.
E4
--
Indoor EEPROM error
Page.32.
E14
--
Indoor fan motor malfunction
Page.33
Outdoor
Malfunction
F12
1
Outdoor EEPROM error
Page.32
F1
2
The protection of IPM
Page.36
F22
3
Overcurrent protection of AC
electricity for the outdoor
model
Page.37
F3
4
Communication fault between the
IPM and outdoor PCB
Page.39
F19
6
Power voltage is too high or low
Page.40
F4
8
Overheat protection for Discharge
temperature
Page.41
F21
10
Defrost temperature sensor failure Page.31
F7
11
Suction temperature sensor failure Page.31
F6
12
Ambient temperature sensor
failure
Page.31
F25
13
Discharge temperature sensor
failure
Page.31
F11
18
deviate from the normal for the
compressor
Page.44
F28
19
Loop of the station detect error Page.44
F2
24
Overcurrent of the compressor
Page.37
F23
25
Overcurrent protection for
single-phase of the compressor
Page.43
F8
9
Outdoor DC fan motor fault
Page.43
Содержание 2U40S2SM1FA
Страница 11: ...Pinping diagrams Domes t ic air condit ioner 4 Pinping diagrams 9 ...
Страница 12: ...Operation range Domestic air conditioner 5 Operation range 10 10 0 21 27 35 20 40 60 43 20 40 ...
Страница 15: ...wiring diagram Domestic air conditioner PCB 1 13 NOTE J3 OFF STATUS ...
Страница 16: ...wiring diagram 14 Domestic air conditioner PCB 2 ...
Страница 33: ...Dimensional drawing 31 Domestic air conditioner 8 Dimensional drawings 9 Center of gravity ...
Страница 63: ...Domestic air conditioner Sincere Forever ...
Страница 64: ...Wall Mounted Type DC Inverter FREE MATCH N Series 2U40S2SM1FA Model No ...