Model 36A00-1 UPB™ Powerline Interface Module

  

 

 

 

 

DESCRIPTION

 

 
The Model 36A00-1 UPB™ Powerline Interface Module (PIM) is a plug-in module designed to interface to a serial port on an 
OmniLT, Omni II, or OmniPro II controller to transmit and receive UPB™ signals over the powerline. 

 
 

INSTALLATION

 

 
Plug the Model 36A00-1 UPB™ Powerline Interface Module (PIM) into a 120 VAC outlet.  Plug one end of the supplied 6 conductor 
modular cable to a serial port on the HAI controller and plug the other end into the modular connector on the Model 36A00-1.   
 
Use the 36A05-2 PIM to PC Cable & Connector (purchased separately) to connect the HAI Model 36A00-1 UPB™ Powerline 
Interface Module (PIM) to a standard DB-9 serial port.  The 36A05-2 is used to connect the PIM to the HAI Model 10A17-1 Serial 
Interface Module for controlling UPB™ devices through an HAI controller, or to a PC for configuring UPB™ devices using the 
UPB™ UPStart configuration software. 
 
 

STATUS LED 

 
The Status LED on the Model 36A00-1 will blink red when it transmits a UPB™ signal on the powerline and it will blink green when 
it receives a valid UPB™ signal over the powerline.  

 
 

PROGRAM BUTTON 

 
HAI controllers communicate with the Model 36A00-1 UPB™ Powerline Interface Module in Message Mode.  While Message Mode 
is the factory default mode of the PIM, the UPB™ UPStart configuration software uses the Pulse Mode of the PIM.  If the PIM is in 
Pulse Mode when connected to an HAI controller, the “Receive” LED on the HAI Serial port will be on steady.  The Program button 
on the left side of the Model 36A00-1 can be used to set the PIM to factory default (i.e. back to Message Mode).  To set the Model 
36A00-1 to factory default, do the following: 
 

Step Operation 

Press the Program button five (5) times quickly in a row. 

The LED should start to blink green to indicate it is in Setup Mode. 

Press the Program button ten (10) times quickly in a row. 

The LED should start to blink red to indicate that the Factory Defaults have been set. 

Press the Program button one (1) more time. 

The LED should stop blinking to indicate that it is ready for normal operation. 

 

Note:

 It is normal for this module to make a slight buzzing sound during operation. 

 

 
 
 

36I00-1, Rev B 