How Your Appliance Works 

Your

WaterMax

®

 Drinking Water Appliance has been designed as a complete, self-contained appliance using 

three stages of primary filtration and separation. The frequency in which membranes and filters should be 
replaced depends upon the quality of the water that enters the appliance (feed water). 

Meeting operational maintenance and replacement requirements are essential for this appliance to perform to 
specification. Contact your local dealer for replacement filters and parts, or contact Hague Quality Water 
International for the dealer nearest you. 

First Stage–The Pre-Filters 

Your RO appliance uses one or more pre-filters to remove impurities before the feed water reaches the reverse 
osmosis membrane. 

Pre-Filter

Model Number 

Function

Sediment

H2000, H2500, H3000, 
LC30, LC50, LC100

Removes suspended and particulate matter 5 microns or larger 
from the incoming tap water to protect the RO membrane and 
any Carbon Pre-Filter from clogging 

Carbon

H3000, LC30, LC50, 
LC100

Removes free chlorine from the feed water and protects the 
membrane from chlorine degradation 

Dual-Function

(combination sediment and 
carbon) 

H3500, LC50P LC100P 

Protects the membrane from clogging and chlorine degradation 

Sediment Pre-Filter Maintenance—Models H2000, H2500, H3000, LC30, 
LC50 and LC100 

If you are using softened water, replace your Sediment Pre-Filter annually. If you are not using softened water, 
the replacement interval will vary. Every six months, schedule an inspection and replace the Sediment 
Pre-Filter as necessary. If you notice a discoloration in the core (center) of the Sediment Pre-Filter and/or a 
heavy accumulation of sediment on the surface of the Sediment Pre-Filter, then replacement is necessary. The 
maximum recommended practical service life of the Sediment Pre-Filter is one year. The pre-filter is overdue 
for change when you notice reduced water production or a slower rate of flow. 

Note:

 The Sediment Pre-Filter performance has not been tested or certified by WQA. 

Carbon Pre-Filter Maintenance—Models H3000, LC30, LC50, and LC100 

Changing the Carbon Pre-Filter should be based on the free chlorine levels in the feed water. If the free 
chlorine is 1 ppm or less, then the Carbon Pre-Filter should be replaced once a year. If the free chlorine level is 
greater than 1 ppm, then the Carbon Pre-Filter should be replaced every six months. 

Note:

 Models H3000, H3500, and LC30 also incorporate a special prolonged contact filter that further reduces 

chlorine and organics from your water supply. 

Dual-Function Pre-Filter Maintenance—Models H3500, LC50P and LC100P 

Follow the same maintenance procedures as for the Sediment Pre-Filter. 

WaterMax RO Owner’s Manual 

11/11/2009

8

Содержание WATERMAX H2000

Страница 1: ...ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E M MO OD DE EL LS S H H2 20 00 00 0 H H2 25 50 00 0 H H3 30 00 00 0 H H3 35 50 00 0 L LC C3 30 0 L LC C5 50 0...

Страница 2: ...y is null and void unless the Hague Appliance was purchased from an independent Hague dealer THERE ARE NO WARRANTIES OTHER THAN THOSE DESCRIBED IN THIS WARRANTY INSTRUMENT This warranty does not cover...

Страница 3: ...LLATION AND MAINTENANCE INFORMATION 13 Checklist Before Installation 13 Installation Tool List 14 Installation Diagram 15 Typical Flow Diagram 16 Booster Pump Retrofit Diagrams 17 Installation Steps a...

Страница 4: ...ht to make specification and product changes without prior notice This manual is for installation operation and maintenance of the following RO appliance models x WaterMax H2000 x WaterMax H3500 x Wat...

Страница 5: ...service this appliance Important Meeting operational maintenance and replacement requirements are essential for this product to perform to specifications Hague recommends that the storage tank be drai...

Страница 6: ...g Water Appliances replenish at about one half gallon per hour depending on your tap water pressure and the water temperature Low water pressure and temperature will cause all RO appliances to produce...

Страница 7: ...Max RO Drinking Water Appliance is designed to be used on cold water only Never run warm or hot water through your appliance Caution Connect to the cold water supply only Warning Do not allow your app...

Страница 8: ...ance Models H2000 H2500 H3000 LC30 LC50 and LC100 If you are using softened water replace your Sediment Pre Filter annually If you are not using softened water the replacement interval will vary Every...

Страница 9: ...monitoring devices or water check programs Note If your WaterMax RO appliance is installed on a soft water supply it will greatly increase the life of the membrane Third Stage Carbon Post Filter The A...

Страница 10: ...installed where the water source is microbiologically unsafe or of unknown quality without adequate disinfection before and or after the appliance A water source that is not potable relative to waterb...

Страница 11: ...ivated carbon as pretreatment for chlorine CAUTION Contaminants in excess of the established limits will require pretreatment WARNING Do not use with water that is microbiologically unsafe or of unkno...

Страница 12: ...blications ordpubs html Private water supplies and waters that do not have detectable free chlorine residuals should be analyzed to determine the form s of arsenic present and the potential need for o...

Страница 13: ...bing codes To prevent back siphoning provide an adequate air gap or a siphon break See Installation Steps and Start Up Procedures Water Characteristics pH The appliance requires a pH of between 5 0 an...

Страница 14: ...ank for non air gap spigot Air pressure test gauge 1 20 psi 1 inch High speed drill bit with 1 2 inch shank for air gap spigot 7 8 inch chassis punch 1 2 inch Drill motor for 1 inch high speed drill b...

Страница 15: ...tallation Diagram Notes 1 For maximum flow keep yellow tubing to tank and blue tubing to spigot as short as practical 2 Install feed water line on COLD WATER LINE ONLY 3 Installation procedures for th...

Страница 16: ...Typical Flow Diagram Air Gap Silencer for H3500 and H2500 Figure 3 WaterMax H3500 Flow Diagram WaterMax RO Owner s Manual 11 11 2009 16...

Страница 17: ...rofit Diagrams WaterMax H2000 For retrofit instructions see form F0873 Figure 4 WaterMax H2000 WaterMax H3000 For retrofit instructions see form F0874 Figure 5 WaterMax H3000 WaterMax RO Owner s Manua...

Страница 18: ...ameter be free of score marks and that burrs and sharp edges be removed before inserting into fitting Insert the locking clip The locking clip secures the collet in its position to prevent an accident...

Страница 19: ...ron sink A Mark the sink location for the center of the faucet Be sure the location you select is not over a reinforcing rib Check the location from below B Grind away a 1 1 4 inch diameter circle in...

Страница 20: ...4 inch black tube onto the small hose barb on the base of the spigot C Slip one end of the loose 3 8 inch black tube over the large hose barb on the base of the spigot Installation Tip To make it eas...

Страница 21: ...ect the riser tube to the other end of the feed water supply valve Do not overtighten Caution A longer riser tube assembly will be required if a gentle loop cannot be made See Figure 8 E Remove the re...

Страница 22: ...el off the white backing from the drain gasket and apply the gasket to the port connection of the drain saddle See Figure 15 Make sure to align the drain saddle to the drilled hole Attach the drain sa...

Страница 23: ...place B Turn on the feed water and check for leaks C Open the valve on top of the storage tank D The appliance is now in operation tep 9 Operation Procedure A Operation of the appliance will require t...

Страница 24: ...visibly dirty discard it 6 Wash out the filter housing using warm soapy water and rinse thoroughly 7 Sanitize the appliance See Sanitizing the WaterMax RO Appliance 8 Be sure the O Ring is properly s...

Страница 25: ...ater supply valve 3 Lift the black handle of the dispensing spigot and wait at least five minutes for the pressure to be relieved from the system 4 Remove the Carbon Pre Filter housing by turning it c...

Страница 26: ...the O Rings on the pressure vessel end cap and lubricate with glycerin Replace if damaged or out of round 10 Replace the end cap by turning clockwise 11 Reattach the tubing to the pressure vessel end...

Страница 27: ...d then rinse thoroughly with clear water to flush away any soap residue Note Be sure all carbon pre and post filters are removed during the sanitizing procedure 4 Insert the new cartridge s for the sp...

Страница 28: ...bottlebrush and then rinse thoroughly with clear water to flush away any soap residue 2 Insert the new cartridge for the specified model Caution Do not touch the filter with your bare hands Peel the w...

Страница 29: ...ts Feed Water Service Valve Assembly 2 1 Figure 13 Feed Water Assembly Part Description Quantity 1 200540 Feed Water Service Valve Assembly 1 2 200200 1 4 inch Locking clip 1 WaterMax RO Owner s Manua...

Страница 30: ...O Air Gap Spigot Lead Free Part Description Quantity 1 202310 Filter housing wrench 1 2 200350 Air gap spigot assembly 1 3 200360 Spigot adapter 3 8 inch x 7 16 inch J G 1 4 200199 Locking clip 3 8 in...

Страница 31: ...arts Cont Drain Saddle Assembly Figure 15 Drain Saddle Assembly Part Description Quantity 1 200130JG Drain saddle assembly 2 Piece Plastic 1 2 200199 3 8 inch Locking clip 1 WaterMax RO Owner s Manual...

Страница 32: ...Assembly and Parts Cont RO Assembly Front View Figure 16 RO Assembly Front View WaterMax RO Owner s Manual 11 11 2009 32...

Страница 33: ...12 inch H3000 H3500 LC30 1 15 200191 Inline nitrate filter Optional 1 16 201165 Pressure vessel O Ring 1 17 200300 CTA membrane 16 GPD H2000 H2500 1 18 200290 TFC membrane 24 GPD H3000 H3500 1 19 2002...

Страница 34: ...Assembly and Parts Cont RO Assembly Back View Figure 17 RO Assembly Back View WaterMax RO Owner s Manual 11 11 2009 34...

Страница 35: ...1 4 inch x 1 4 inch 1 9 202356 Reducing tee 3 8 inch x 3 8 inch x 1 4 inch Plastic 1 10 PAMC Mounting clip permeate pump 1 11 PAM1000 Permeate pump H2500 H3500 LC50P LC100P 1 12 200095 16 Flow restri...

Страница 36: ...Assembly and Parts Cont RO Assembly Top Back View Figure 18 RO Assembly Top Back View WaterMax RO Owner s Manual 11 11 2009 36...

Страница 37: ...99 Locking clip 3 8 inch 3 9 90816 Male elbow 3 8 inch x 1 4 inch Plastic 1 10 202349 Plug in elbow 1 4 inch tube x 1 4 inch Stem 3 11 200245CJG Membrane housing cap black with O Ring 1 12 201030 Male...

Страница 38: ...rage Tank Assembly Part Description Quantity 1 201140 Tank shutoff valve 3 8 inch x 1 4 inch plastic 1 2 200199 3 8 inch Locking clip 1 3 200100 RO storage tank 3 1 gallon capacity black 1 4 200030 Ta...

Страница 39: ...p Kit P N PAB6800KIT Figure 20 Parts Booster Pump Kit Part Description Quantity 1 PAB6800 Booster pump 1 2 PAT115 Transformer 24VAC 1 3 PAW260 Pressure switch 1 4 200910 1 4 inch x 5 foot tubing red 1...

Страница 40: ...pump 1 202349 Plug in elbow 1 4 inch tube x 1 4 inch stem 4 PAMC Mounting clip permeate pump 1 200500 Screw 10 32 x 1 2 inch Phillips 2 200501 Hex nut 10 32 Nylock 2 PAMASV Permeate pump shut off valv...

Страница 41: ...ater shut off Turn on your feed water valve Low feed pressure See Filter Specifications chart to verify minimum feed pressure for your model A pre filter cartridge clogged Replace the clogged pre filt...

Страница 42: ...cube mold shape make cubes manually if using automatic Let water sit to release dissolved air before freezing RO membrane is bad Membrane fouled hydrolyzed ruptured or attacked by bacteria Replace mem...

Страница 43: ...bon Block 5 Micron Sediment GAC 5 Micron 20 inch Sediment GAC 5 Micron 20 inch Sediment GAC PCF N A N A Standard Standard Standard N A N A Postfilter GAC GAC GAC GAC GAC GAC GAC Height inches 15 1 4 1...

Страница 44: ...Certificates WaterMax RO Owner s Manual 11 11 2009 44...

Страница 45: ...Certificates Cont WaterMax RO Owner s Manual 11 11 2009 45...

Страница 46: ...Notes...

Страница 47: ...Notes...

Страница 48: ...uality Association This validation assures that all electrical components are UL or CSA listed and all components that are in contact with the treated water are FDA or NSF listed Hague Quality Water I...