ELECTRICAL SPECIFICATIONS AND COLOR CODES FOR WIRES 

For use with all Hager monitored exit device modifications.   
Request to Exit (RX) switch monitors egress by push bar activation of the exit device. 

Latch Bolt Monitoring (LM) switch monitors the latch mechanism of the exit device. 

Authorized Ingress (AI) switch monitors ingress by trim or key retraction of the exit device latch. 

 

 

Request to Exit (RX) 

Latch Bolt Monitoring (LM) 

Authorized Ingress (AI) 

Electrical 
Specification 

SPDT Monitoring Switch 
 

Maximum Contact Rating: 
3 AMP @125VAC 

2 AMP @ 30VDC 

SPDT Monitoring Switch 
 

Maximum Contact Rating: 
3 AMP @125VAC 

2 AMP @ 30VDC 

SPDT Monitoring Switch 
 

Maximum Contact Rating: 
3 AMP @125VAC 

2 AMP @ 30VDC 

Color Code 

for wires 

Yellow Wire – Common 

Red Wire – Normally Open 
Grey Wire – Normally Closed 

Wire Gauge – #22 AWG 

Black Wire – Common 

White Wire – Normally Open 
Red Wire – Normally Closed 

Wire Gauge – #22 AWG 

Black Wire – Common 

Orange Wire – Normally Open 
Purple Wire – Normally Closed 

Wire Gauge – #22 AWG 

 
WIRE ROUTING AND DOOR PREP INSTRUCTIONS 

1.

 

Follow exit device instructions and template to prepare door and frame for installation. 

2.

 

Door fabricator to provide a 3/8” ** diameter (minimum) raceway through door to allow insertion of 
electrical wires running between exit device and power transfer device (electric hinge). 

        

 

Door fabricator to provide a  

3/8” ** diameter (minimum) 

Raceway through door to  

Allow insertion of electrical  

Wires running between exit 

Device and power transfer 

device

**

DEVICES COVERED IN THIS DOCUMENT: 
 
LM – Latch Bolt Monitoring * 

 

 

 

 

 

DE – Delayed Egress 

ELR – Electric Latch Retraction (not for use with Mortise Exit)*   

AI – Authorized Ingress * 

RX – Request to Exit (Field Installation Kit 2-649-5001) *  

 

RX2 – Dual Request to Exit 

ED – Electric Dogging *   

 

 

 

 

 

ET – Electric Trim (4500 Series only) 

EL or EU – Electrified Mortise Trim (ordered with 4501N Exit) *   

OBDE-On-Board Delayed Egress 

MLR – Motorized Latch Retraction (Field Installation Kit 2-649-5007) * 
 
* Quick Connects Optional 

** Quick Connects Require 5/8” Raceway 