background image

I

N T R O D U C T I O N

– 1 –

The 

Hafler P4000

 is a three rack height, two channel professional power amplifier suitable for use in any

situation where a moderately powered compact amplifier is required. The P4000 is particularly attractive for

use in monitoring situations. Our trans•

nova

 circuit topology and MOSFET output stage ensures trouble-free,

long term operation and is backed by our five year warranty.

This manual contains information on using the P4000 amplifier. It is organized into three main sections.

“Installation”

 covers the location and connection of the amplifier in the system. Like many precision

components, careful attention to the initial setup can yield dividends in higher performance and trouble-free

use. 

“Operation”

 covers the controls and features of the amplifiers and how to use them to get the best effect.

The 

“Technical Reference”

 section contains field service information; in addition to the schematic  and parts

list there are block diagrams and circuit operation explanations useful for technicians. We strongly urge

reading over the Installation and Operation portions of this manual before putting the amplifier into service.

The circuitry used in the Hafler Professional power amplifiers is our

 trans•

nova

 (

TRANS

conductance 

No

dal

V

oltage

  A

mplifier, U.S. Patent 4,467,288) circuit. The P4000 also utilizes our proprietary 

DIAMOND

(

D

ynamically 

I

nvariant 

AM

plification 

O

ptimized 

N

odal 

D

rive, patent pending) transconductance driver stage

which combines the linearity of Class A operation with the current headroom of a Class B system. When

combined with the robust output stage used in the P4000, DIAMOND yields lower high frequency distortion

without the sonic degradations associated with increasing the negative feedback. We have been using

MOSFETs in our power amplifiers since the 1970's. During this time they have proven to be extremely fault

tolerant, even in abusive situations. This ruggedness enables the amplifier to drive reactive speaker loads

without the performance and sound degradations imposed by elaborate Safe Operating Area protection

schemes.

Other specialized circuits which prevent damage to the amplifier and speakers have been carefully imple-

mented. A soft start circuit prevents sending potentially destructive turn-on and turn-off transients to the

speakers. A thermal sensing network continuously monitors the heatsink temperature and shuts down the

amplifier to protect it from excessive operating heat. The need for internal fuses has been eliminated; a sensing

circuit monitors the output and shuts down operation when it detects a short at the output.

Each channel of the amplifier has been built as a self-contained module. This modular arrangement simplifies

construction and improves service accessibility. The circuit board assembly makes extensive use of surface

mount components in the low power portion of the audio circuitry. Automated equipment is used to place and

solder the components which yields greater uniformity and reliability.

The front panel has controls for input level adjustment and the power switch. In addition, LED indicators give

a visual representation of the operating status of each channel. The THERMAL and SHORT indicators light to

show when these protection circuits have been activated. The CLIP indicator helps prevent damaging the

speaker by showing when the amplifier is overdriven. The SIGNAL indicator lights to show the presence of an

audio signal.

Содержание trans-nova P4000

Страница 1: ...PROFESSIONAL POWER AMPLIFIER P4000 Installation Operation PROFESSIONAL POWER AMPL nova trans DESIGNED AND ASSEMBLED IN THE U SA...

Страница 2: ...of the equipment s plug be able to fully insert into the mating receptacle Never remove the round grounding pin on the plug in an attempt to mate to a two wire ungrounded receptacle use a grounding ad...

Страница 3: ...s CMRR 75dB at 1kHz Input Impedance 47 000 per phase balanced Input Sensitivity Range 710mV to 4V 8 per phase balanced 592mV to 4V 4 per phase balanced In Out Gain 29dB maximum 29dB minimum Gain Contr...

Страница 4: ...ATION Power Switch 6 Level Controls 6 Input Configuration Switch 6 Ground Switch 7 Short Circuit Protection 7 LED Indicators 7 Warm Up 7 Cleaning and Maintenance 7 TECHNICAL REFERENCE Field Service Co...

Страница 5: ...AMOND yields lower high frequency distortion without the sonic degradations associated with increasing the negative feedback We have been using MOSFETs in our power amplifiers since the 1970 s During...

Страница 6: ...ade in the U S A Audio Ground Chass Float C H 1 8 C A U T I O N RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING DO NOT REMOVE COVER TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT...

Страница 7: ...20cm hinter der Front des Verst rkers angebracht werden Per i sistemi ad armadio sono necessari due ventilatori direzionati in su collocati dai 10 ai 13 centimetri davanti all amplificatore Inadequate...

Страница 8: ...INPUT FROM SOURCE 1 2 3 GND 1 2 3 SHIELD SHIELD SHIELD INPUT The input jacks located on the back of the amplifier are dual function connectors which accept 1 4 Phone Tip Ring Sleeve or XLR plugs The 1...

Страница 9: ...dged amplifier shares the load between the two channels each channel will effectively drive half of the load Therefore for bridged mono operation we recommend using an eight ohm load as the minimum im...

Страница 10: ...by 60dB and are marked from 10 full output to 0 full attenuation In public systems where it is necessary to match levels the knobs can be removed and the controls adjusted with your fingers or a flat...

Страница 11: ...Lautsprechern oder in den Lautsprecherkabeln wird eine Schutzschaltung aktiv die den entsprechenden Kanal abschaltet Auf der Frontseite wird dies mit einer LED angezeigt Sollte dies einmal passieren b...

Страница 12: ...ently increases the power gain for the same bandwidth of the output stage by typically ten times over the conventional follower connection using the same MOSFET devices This increase in efficiency all...

Страница 13: ...erential Amp Q6 Q7 Current Mirror Q104 Q105 Positive Driver Cascode Q9 Q10 Feedback Network Drive Signal Local Feedback Bias Adjust R136 Positive Output Q4 Q15 Q115 B Output B Negative Output Q5 Q16 Q...

Страница 14: ...SC H E M A T I C DI A G R A M NOTES Unless specified otherwise 1 All resistors in ohms 2 All capacitors in microfarads 3 Channel 1 only shown 10...

Страница 15: ...PRI B PRI A BLK WHT BLK WHT 60 HZ NEUTRAL LINE BLK BLK WHT 15A SLO BLO WHT BLU BLU BLU AC4 AC3 CT2 WHT ORG RED BLU CT1 ORG ORG AC AC BRIDGE RECTIFIER GROUND GRN YLW AC CAPACITOR Model P4000CE 6 3A SLO...

Страница 16: ...12 PC BO A R D LA Y O U T PC 1487 C...

Страница 17: ...92 Q2 LM 317 Regulator SS 1375 Q3 LM 337 Regulator SS 1376 Q4 N Channel MOSFET SS 741T Q5 P Channel MOSFET SS 740T Q6 MMBT5088L SS 0114 DESIGNATOR VALUE PART ALL RESISTORS IN OHMS R1 56 2k 1 4W 1 RMP...

Страница 18: ...U4 LM339 Quad Comparator SS 730SM U5 LM339 Quad Comparator SS 730SM Power Switch SWH 1009 IEC Connector CC 0852 IEC Line Cord FAH 146 Transformer TT 1501 B Bridge Rectifier 25 Amp SSH 609 Thermistor 1...

Страница 19: ...ut devices have been changed or if the two channels of the amplifier do not run at the same temperature calibrating the bias is necessary Disconnect the power to the amplifier before removing the cove...

Страница 20: ...A on pin 7 the Output Signal is connected to the input of U4A on pin 6 The output of U4A goes low when pin 7 is low and pin 6 is near zero This condition indicating high drive voltage and low output v...

Страница 21: ...RMAL indicator Clipping Indicator SIGNAL Indicator CR4 LED Driver Q8 Signal Detector U5D Amplifier Output CLIP Indicator CR3 LED Driver U5C Clipping Detector U5A Drive Signal The CLIP indicator is dri...

Страница 22: ...d remove it from the amplifier Take the knobs off the level controls 2 Remove the 9 64 Allen screw located behind the rack ears and the three 9 64 screws on the bottom edge of the heatsink This frees...

Страница 23: ...rformed by anyone other than Hafler or an Authorized Hafler service center 3 Any product purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafl...

Страница 24: ...tensiones deben proveer de la misma conecci n aterrada de tres hiles Es importante que el enchufe se pueda introducir comjpletamente en el recept culo Nunca remeva el pin de aterramiento en un intento...

Страница 25: ...consell e moins d tre en mesure de fournir la charge lectrique requise un fonctionement sans risque de tout mat riel reli 11 P RIODES DE NON UTILISATON Durant les p riodes de non utilisation la prise...

Страница 26: ...dies die erforderlichen Str me bertragen k nnen Benutzen Sie immer dreiadrige Verl ngerungskable 11 ZEITR UME IN DENE DAS GER AT NICHT GENUTZT WIRD Wird das Ger t ber einen l ngeren Zeitraum nicht ge...

Страница 27: ...uesti non garantiscono la potenza sufficiente per i corretto fuinzionamento degli apparati connessi E alters importante che vengano sempre impiegate prolunghe con la configurazaione a tre fili con ter...

Страница 28: ...6 97 HAFLER PROFESSIONAL A DIVISION OF ROCKFORD CORPORATION 546 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 U S A IN U S A 602 967 3565 IN CANADA 604 942 1001 IN EUROPE FAX 8503 9340 14 IN JAPAN FAX 81 5...

Отзывы: