the bias level is such that the transistors won’t wonder into a thermo runaway condition and the driver 

stage will not fall out of class A operation.  

The change in the bias of the driver stage affected the current through the output transistors as 

expected. P2 controls the current and should be set to 400 milliamps as explained in the owner’s manual. 

The output transistors operate in Class B as a push pull amplifier. It is important that current through all 8 

transistors never drops to zero in order to prevent crossover distortion. Another test showed that at full 

output power the current only nears zero if the bias current is set at or below 250 milliamps. Since the 

owner of this amplifier will not be using it anywhere near its limits, the bias was set at 350 milliamps. 

This will provide plenty of current at crossover and has the added benefit of cooler transistors and 

heatsink. I consider the overheating transistor problem solved, but if my friend encounters a problem, I 

can always increase the bias level if needed.   

The source of the turn on and turn off thumping problem turned out to be far more difficult to 

locate. The use of an oscilloscope showed a 50-volt spike at the amplifier’s output right after turn-off. The 

source of the spike appeared to be everywhere and nowhere specific. All DC measurements were normal. 

The amplifier’s output is feedback to both sides of a current mirror consisting of Q8, Q11 and U9. This 

made it difficult to pin down the exact source. The first area I looked at was of course the turn-on turn-off 

control circuit which is part of the power supply and consist of 3 transistors, Q201, Q202, Q203, a few 

diodes, capacitors, and resistors. This circuit controls Q10, a transistor biased to sink around 11 ma. It 

delays the turn on of the current source at power up and shuts it down very quickly at power off. This 

circuit was found to be operating correctly. By using a multi-channel oscilloscope, it was found that Q12 

was still conducting for a short period of time after the current source had been shut off. It was this 

current that generated the pulse that was applied to the base of the P channel MOSFETs. The replacement 

of Q12 ended the thumping problem but during the process of finding Q12, it was discovered that several 

of the P-channel MOSFETs were leaking. Probably damaged by the erroneous spike. It is easy to tell if 

there are leaky transistors in the output stage. The transistors are all enhancement mode MOSFETS and 