background image

– 34 –

INPUT

Содержание SR2300

Страница 1: ...Owner s Manual Owner s Manual SR2300 SR2600 SR2300 SR2600...

Страница 2: ......

Страница 3: ...Output 13 Power Switch 13 OPERATION 14 Input 14 Daisy Chain Output 14 Earth Grounded Equipment 14 Floated Equipment 15 Level Controls 15 Biamp Stereo Switch 16 Stereo Mono 70V 100V Switch 16 Protect 1...

Страница 4: ...y Manufacturer s Name Hafler Manufacturer s Address 546 South Rockford Drive Tempe Arizona 85281 Importer s Name Importer s Address Type of Equipment 2 channel Audio Power Amplifier Model No SR2300CE...

Страница 5: ...receptacle Never remove the round grounding pin on the plug in an attempt to mate to a two wire ungrounded receptacle use a grounding adapter with the grounding tab or wire suitably connected to eart...

Страница 6: ...esto no ocurra como podr a suceder debajo de una alfombra o al pasar el cable por una esquina aguda etc 10 ATERRAMIENTO DEL CABLE DE CORRIENTE El cable de corriente es del tipo aterrado de tres hilos...

Страница 7: ...e Verl ngerungskable 11 ZEITR UME IN DENE DAS GER T NICHT GENUTZT WIRD Wird das Ger t ber einen l ngeren Zeitraum nicht genutzt z B Urlaub ziehen Sie bitten den Netzstecker aus der Steckdose 12 REINIG...

Страница 8: ...tionement sans risque de tout mat riel reli 11 P RIODES DE NON UTILISATON Durant les p riodes de non utilisation la prise de courant ne devrait pas tre branch e une source d energie 12 NETTOYAGE Le ma...

Страница 9: ...arati connessi E alters importante che vengano sempre impiegate prolunghe con la configurazaione a tre fili con terra 11 PERIODI DI NON UTILIZZO Durante lunghi periodi di non utilizzo staccare il cavo...

Страница 10: ...ANCE 47k per phase balanced 47k per phase balanced DAMPING FACTOR 500 500 POWER THERMAL REQUIREMENTS Idle Condition 55W 70W U version 860mA 115VAC 1 0A 115VAC CE version 430mA 230VAC 500mA 230VAC Ther...

Страница 11: ...g an amplifier of outstanding audio qualities high effi ciency and unprecedented value TRANS nova Class G is that answer The most common high efficiency Class H methods raise the rail voltages going t...

Страница 12: ...plifier is turned on This serves the dual function of cleaning out the air tun nel and providing a simple means to check the fans for proper operation If you suspect that the fans are not operating co...

Страница 13: ...spade lugs or dual banana plugs to be connected to the amplifier 11 Internal Fans internal fans keep the amplifier circuitry cool Allow a minimum of 3 clearance on the front and back of the amplifier...

Страница 14: ...ve included AC mains current draw and thermal dissipation values in the Specifications Sheet The specifications listed are for idle no sig nal 1 8th power normal operating conditions for continuous vo...

Страница 15: ...ted to the Chassis and AC mains earth ground This connection is made through a 0 resistor R350 located on the input board The resistor serves as a fuselink in the case of severe system faults To check...

Страница 16: ...output ground connected to the earth grounded chassis This can be verified with an ohmmeter by disconnecting the mains power cord from the AC outlet and checking for continuity between the earth groun...

Страница 17: ...through of all 3 pins of the input jack LEVEL CONTROLS The gain for each channel can be controlled individually using the front panel level control The controls have 32 detented positions that are cal...

Страница 18: ...o mode also use the CH B input connector and level control only The 70V or 100V speaker array load should be connected across the red terminals of the output connectors Set both load switches to the a...

Страница 19: ...level control all the way OFF If the clipping continues then the signal is clipping at the amplifier input Input clipping occurs at 3Vrms sine and can be eliminated by attenuating the signal before it...

Страница 20: ...input Load across RED terminals Set load switches to one half load impedance A Division of Rockford Corp Tempe AZ 85281 Made in the U S A S R 2 3 0 0 300 W Stereo 2 8 600W Mono 70V 100V Mono 250W 100...

Страница 21: ...0 Volt Transformer 70 Volt Transformer Parallel Array etc 100V 70V 100V 70V SR2300 SR2600 1 Connect signal from source to CH B input 2 Biamp Stereo switch not active Stereo Mono switch overrides this...

Страница 22: ...d rating of fuse 4 16 100 Volt Transformer 100 Volt Transformer Parallel Array etc 100V 70V 100V 70V SR2300 SR2600 Power 70V 4 Load 2 100V 8 70V 4 2 100V 8 BIAMP STEREO CH A IN 300W 2 8 Mono 70V 100V...

Страница 23: ...roduct purchased outside the United States please contact your local dealer 4 Shipping charges to get the unit to Hafler 5 Any product which has had the serial number defaced altered or removed Limit...

Страница 24: ...R150 R160 R147 R146 R145 R142 R139 R138 R137 R119 R135 R131 R129 R120 R118 R132 R121 CR53 CR52 CR29 CR24 C60 C59 C58 C57 JW6A1 16 1 C124 C133 U14 U13 SW3 SW2 R295 R293 R290 R283 R294 R288 C128 C130 R...

Страница 25: ...23 J9 J10 J16 J3 J5 J1 C5 C3 C2 R2 L2 L1 L3 C6 C1 C4 R3 C7 R1 J12 J11 R4 J8 J15 J13 J7 J6 J14 DANGER HIGH VOLTAGE 230V 230V 120V 120V ORG ORG WHT WHT BLACK BLACK KS4R PC 2460 E HAFLER J4 J2 EMI FILTER...

Страница 26: ...24 Schematic Diagrams PC 2460 e sch 1 EMI FILTER...

Страница 27: ...25 C600_maualB sch 4 BRIDGE RECTIFIER...

Страница 28: ...26 AMPLIFIER...

Страница 29: ...27 C600_maualB sch 1...

Страница 30: ...28 PROTECTION...

Страница 31: ...C600_maualB sch 2 29...

Страница 32: ...30 HIGH VOLTAGE CONTROL...

Страница 33: ...31 C600_maualB sch 3...

Страница 34: ...32 HOUSEKEEPING CONTROL...

Страница 35: ...33 C600_maualB sch 6...

Страница 36: ...34 INPUT...

Страница 37: ...35 C600_maualB sch 8...

Страница 38: ...36 POWER...

Страница 39: ...37 C600_maualB sch 5...

Страница 40: ...IVISION OF ROCKFORD CORPORATION 546 SOUTH ROCKFORD DRIVE TEMPE ARIZONA 85281 U S A IN U S A 480 967 3565 IN CANADA 604 942 1001 IN EUROPE FAX 8503 9340 14 IN JAPAN FAX 81 559 79 01265 MAN 2568C 5 00 M...

Отзывы: