eLImINATING GRouNd LooPS uSING AudIo GRouNd ISoLAToR

If all is well with the electrical outlets, but you are encountering noise, adding an isolation transformer module in between your preamp 

and amplifier can help eliminate the noise. If you are only using the bus input on the CI-1255e, the easiest solution is to add a CI-9022 

or CI-9024 into the Omniport. This is easily done by following the instructions that come with the module. Once installed, connect the 

source to the isolation module input and enjoy the noise-free solution! 

If you plan to use multiple sources, the same ‘start backwards’ rule applies. Add one source at a time and listen. If you encounter noise, 

try introducing an isolation transformer in series between the source and the amp input. The Jensen CI-2RR is a wonderfully effective 

device that will not deteriorate the audio quality. 

Introducing a video isolator into your system

One of the most common noise makers is the cable TV connection. Your cable TV is not powered by your home electrical system, but 

it is instead powered by a distant cable TV sub station. With two power sources, it is easy to understand how this can pose a problem.  

To determine if a cable TV connection is responsible for the hum, first turn off all the components. Disconnect the cable TV feed to 

your system. Turn your system back on, and listen if the hum has disappeared. If removing the cable TV feed has eliminated the hum, 

you will need to insert a Ground Loop Isolator like the Jensen VRD-1FF before reconnecting the cable TV feed. These are effective at 

stopping hum and will pass analog and digital signals without hampering the performance. 

WARNING

If you are hearing distorted sound, turn the volume down immediately. Check to make sure the speakers are in proper working 

order and no faults are found with the cables.  Failure to head this warning could result in speaker and/or amplifier damage that 

is not covered by the warranty. If this problem persists, contact your dealer.  

WARNING

If you suspect that the grounding system in the home’s electrical wiring is causing the hum problem, it is important that you do not 

make any changes to the wiring yourself. Only a licensed electrician should make any changes to household wiring and they must 

be made in full compliance with all local building, safety and electrical codes.  

Содержание CI-1255e

Страница 1: ...CI 1255e User Guide 12 Channel Multi Zone Power Amplifier Hafler is a division of Radial Engineering Ltd 1588 Kebet Way Port Coquitlam BC Canada V3C 5M5 604 942 1001 info hafler com www hafler com ...

Страница 2: ......

Страница 3: ... experienced professionals it is in fact easy to use It is important to note that the design features a number of functions that are worthy of your full understanding So before you start connecting wires please take some time to read through this short manual After you have done your homework if you find yourself asking questions please visit the Hafler FAQ page This is where we post questions fro...

Страница 4: ...ng in a 19 rack ensure at least a single rack space is provided above and below the amplifier to assure proper ventilation 8 Do not ever cut or cheat the 3rd safety prong it is there for your safety 9 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments and or accessories specif...

Страница 5: ...many of the stereo pairs as you like The CI 1255e is turned on and off via the front panel power switch and with ECOSYSTEM it automatically turns itself off when no signal is present for energy savings The CI 1255e will automatically spring back to life in 10 milliseconds as soon as signal is detected The front panel also has a power present indicator and an ECOSYSTEM indicator that illuminates wh...

Страница 6: ... extra durability 4 PoWeR Led Lets you know the CI 1255e is powered up and working 5 eCoSySTem Power saving feature automatically sets the amplifier on standby when audio signal is inactive for over a minute Automatically comes to life in 10 milliseconds as soon as signal is detected on any channel 6 eNCLoSuRe Compact 17 x 3 5 x 11 5 432 x 89 x 292mm solid steel enclosure 7 RACk eARS Optional rack...

Страница 7: ...ts signal presence rear mounted to simplify setup when configuring and testing system 14 SPeAkeR Euroblock Phoenix style detachable screw down connectors for quick easy and reliable connectivity to the loudspeaker wires Handles 18 to 10 gauge wire 15 omNIPoRT module input slot expands connectivity with optional Dante digital network card unbalanced Euroblock input connectors transformer isolation ...

Страница 8: ...ant if rack mounting more than one amplifier in your rack If being used this way you can remove the large feet using a Philips 2 screwdriver Be sure to use the rack ear hardware supplied with the kit Longer mount screws may contact internal parts that may cause critical safety violations HIGH CURRENT AMPLIFIER 12 X 55 WATTS 2 3 4 5 6 7 8 9 10 11 12 CLIP SIGNAL CI 1255e POWER 1 BUS IN Hafler TM OPE...

Страница 9: ...d provide an effective and safe means of eliminating system noise Connecting the speaker cable from the CI 1255e is done using a series of detachable euro block Phoenix style connectors These snap in and out of place for a secure lock and the wire is inserted and the screwed down into place using a flat blade screwdriver or tweaker Disconnect the euro block connectors from the amp to connect the s...

Страница 10: ... the source and the bridged amplifier When connecting the cable make sure you connect the speaker using the two OUTSIDE terminals You should also increase the wire gauge size to compensate for the extra power as this will reduce the loss due to heat dissipation in the cable The minimum subwoofer impedance is 8 ohms CoNNeCTING The INPuTS There are several ways to connect to the CI 1255e from your s...

Страница 11: ...have as many or as little channels connected to the bus and these do not have to be in any particular order Simply activate to suit your setup requirements A handy 3 5mm TRS input on the front panel allows you to connect audio from a laptop tablet phone or even a Bluetooth adaptor The front panel 3 5mm input is in parallel with the rear panel BUS RCA inputs Do not attempt to use both at the same t...

Страница 12: ...n the out position You can also mix and match by having some of the channels fed by the bus and others fed by individual source programs A common application could be a hotel lobby and bar whereby you may want to have the lobby supplied with gentle background classical music while the bar would be fed some rock and roll Zone 6 Bridge Mono Zone 1 Zone 2 Zone 5 Zone 4 Zone 3 Rock Playlist Classical ...

Страница 13: ...ing a cell phone or tablet as a source during setup is made easy with the 3 5mm front panel input Start with the trim controls fully open fully clockwise and your preamp turned down Turn on the source material and the amplifier check the LEDs to make sure signal is being received and turn up the preamp until the desired level is achieved If any of the zones are too loud you can use a tweaker or a ...

Страница 14: ...nge the cables one at a time to determine if one or all cables are responsible If the hum disappears when the input cables are disconnected but returns after the cables are changed and the system reconnected your source device may be causing the problem Try the same process by replacing the cables one at a time to see if you can locate a problem Starting Backwards If after testing your cables you ...

Страница 15: ...instead powered by a distant cable TV sub station With two power sources it is easy to understand how this can pose a problem To determine if a cable TV connection is responsible for the hum first turn off all the components Disconnect the cable TV feed to your system Turn your system back on and listen if the hum has disappeared If removing the cable TV feed has eliminated the hum you will need t...

Страница 16: ...er cable is connected 2 Make sure the power switch is pushed in in the ON position 3 Check the signal present LEDs to make sure source signal is being received Speakers pops when amp turns on or off 1 The speakers may need a resistor placed across the amp terminal 2 We suggest 2k0 W resister 3 This will discharge the speaker output s internal capacitor Speakers sound as if lacking bass 1 Out of ph...

Страница 17: ...that is rated higher than the recommended impedance The efficiency of the system will be reduced and the system will not play as loud Can I stack more than one amplifier on top of each other Yes but this must be done in such a way to ensure proper ventilation If stacked on a shelf ensure the large feet are employed and that the sides and back are free from obstructions If you are rack mounting the...

Страница 18: ...20Hz to 20kHz IMD Distortion 0 01 60Hz Common Mode Rejection 70dB direct coupled 90dB with Jensen transformer option Dimensions 17 x 3 5 x 11 5 432 x 89 x 292mm HushTone Fan Noise 22dB maximum Power Maximum 750 watts at 117VAC or 230VAC Gain control 40dB to 20dB for each channel Weight 24lbs 11kg Storage Temperature 40 to 120 C Working Temperature 5 to 40 C Voltage Requirements 115V 60 Hz 230V 50H...

Страница 19: ... RIGHT 1 LEFT 2 RIGHT L R L R PROCESS ECO DETECT LEFT LEFT RIGHT RIGHT 3 LEFT 4 RIGHT L R L R PROCESS ECO DETECT LEFT LEFT RIGHT RIGHT 5 LEFT 6 RIGHT L R L R PROCESS ECO DETECT LEFT LEFT RIGHT RIGHT 7 LEFT 8 RIGHT L R L R PROCESS ECO DETECT LEFT LEFT RIGHT RIGHT 9 LEFT 10 RIGHT L R L R PROCESS ECO DETECT LEFT LEFT RIGHT RIGHT 11 LEFT 12 RIGHT L R L R BUS INPUT 3 5mm or REAR RCA s L R Ci1255e BLOCK...

Страница 20: ...warranty period expires The product must be returned prepaid in the original shipping container or equivalent to Hafler or to an authorized Hafler repair centre and you must assume the risk of loss or damage A copy of the original invoice showing date of purchase and the dealer name must accompany any request for work to be performed under this limited and transferable warranty This warranty shall n...