background image

PARTS LIST

Parts values and types subject to change without prior notice.

DESIGNATORS

1 -99: LEFT CHANNEL

DESIGNATOR VALUE

101-l 99: RIGHT CHANNEL

201-299: COMMON PARTS
301-399: CHASSIS/POWER SUPPLY

C8,C108
C9,C109
C10,C110

DESIGNATOR VALUE

ALL RESISTORS  1/4  WATT,
(unless specified otherwise)

R1,R101           1.1K

R2,R102          22.1K
R3,R103          47.5
R4,R104 4 7 . 5
R5,R105

10K

R6,R106

681

R7,R107

1 0

R8,R108

681

R9,R109

2.21K

R10,R110

5K,  5 Watt

R11,R111

2 2 . 1   K

R12,R112

 

1K

R13,R113

1.1K

R14,R114

22.1K

R15,R115

1 0

R16,R116

3 3 . 2

R17,R117

4 7 . 5

R18,R118

4 7 5

R19,R119

1 0

R20,R120

221

R21  ,R121

221

R22,R122

4 7 . 5

R23,R123

1 0

R24,R124

1 0

C11,C111

PART NUMBER

C12,C112

1 %   M E T A L   F I L M

R25,R125

30,  .5 W, Carbon

R26,R126

2.7, 1  W, Metal

R27,R127

10, 2 W, Metal

R28,R128

1 0

R201

22.1K

R 2 0 2

1K

R 2 0 3

5.11K

R 2 0 4

1K

R 2 0 5

5.11K

R 2 0 6

5.11K

R 2 0 7

10K

R 2 0 8

10K

R 2 0 9  100K

R 2 1 0

12.1K

R211 3.3K, .5 W, Carbon
R 2 1 2

4 7 5 K

R 2 1 3

10K

R 2 1 4

2 2 1 K

R 2 1 5  1.0M
R 2 1 6  1.0M
R 2 1 7  47.5K
R 2 1 8

4 7 . 5

VR1,VR101

50K Volume

P1,P101

P2,P102

1 K Trim
5 0 0   T r i m

RMP/4-1101
RMP/4-2212
RMP/4-0475

RMP/4-0475
RMP/4-1002
RMP/4-6810
RMP/4-0100
RMP/4-6810
RMP/4-2211
RWB5-502
RMP/4-2212

RMP/4-1001
RMP/4-1101
RMP/4-2212
RMP/4-0100

RMP/4-0332
RMP/4-0475
RMP/4-4750
RMP/4-0100
RMP/4-2210
RMP/4-2210
RMP/4-0475

RMP/4-0100
RMP/4-0100
RC/2-300
RM1-027
RM2-100
RMP/4-0100

RMP/4-2212
RMP/4-1001
RMP/4-5111
RMP/4-1001
RMP/4-5111
RMP/4-5111

RMP/4-1002
RMP/4-1002
RMP/4-1003
RMP/4-1212
RC/2-332
RMP/4-4753

RMP/4-1002
RMP/4-2213
RMP/4-1004
RMPM-1004

RMP/4-4752
RMP/4-0475

RVH-503G

RV-102
RVH-501A

C13,C113
C14,C114
C15,C115
C16,C116
C201
C202
C203
C204
C301
C302
C303
C304

0.001,Polypropylene
1 0 0 ,   E l e c t r o l y t i c

0.1,  Polyester
0.1,  Polyester
0.033,Polypropylene
0.1,  Polyester

1 0 0 ,   E l e c t r o l y t i c

0.1,  Polyester
0.1,  Polyester

1 0 ,     E l e c t r o l y t i c
0.1,  Polyester

2 2 0 ,   E l e c t r o l y t i c

1 0 0 ,   E l e c t r o l y t i c

6 8 0 0 ,   E l e c t r o l y t i c
6 8 0 0 ,   E l e c t r o l y t i c
0.01, Ceramic
0.01, UL Approved

Q1 ,Q101

2N5550

Q2,Q102

2N5550

Q3,Q103

2N5401

Q4,Q104

2N5401

Q5,Q105

2N5550

Q6,Q106

2N5401

Q7,Q107

2N5401

Q8,Q108

2N2222A

Q9,Q109

2N5550

Q10,Q110

2N5401

Q11,Q111       2N5550
Q12,Q112

2SK1056

Q13,Q113

2SJ160

Q14,Q114

2N5550

Q 2 0 1

MPSAO6

U1

TS1
T S 2

L M 3 3 9

Thermal Sensor
Thermal Sensor

CR1  CR1  01
CR2,CR102
CR3,CR103
CR4,CR104
CR5,CR105
CR6,CR106
CR7,CR107
CR8,CR108
CR9,CR109
CR14,CR114
CR15,CR115
C R 2 0 1
CR202
BR301
J1,J101
J2
J102
J201

1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N4148
1N5245B, 15V
1N5239B, 9.1V
Diode Bridge
RCA Jack
Left Binding Post
Right Binding Post

AC Voltage Selector

Header:
H o u s i n g :
P i n s :
IEC Connector

J301

ALL CAPACITORS IN MICROFARADS

(unless specified otherwise)

C1,C101

2.2, Polypropylene

CPP-205C

C2,C102 220p,   Polypropylene CPP-221
C3,C103 330p,  Polypropylene CPP-331
C4,C104

1 0 0   N P   E l e c t r o l y t i c

CERNP-107

C5,C105

47p,  Mica

CM-470

C6,C106           220p, Polypropylene CPP-221
C7,C107

3p,  Mica

CM-030

S1

S301

F1,F101

F2,F102

LINE FUSE

Stereo/Mono Switch
Power Switch

5   A m p   3 A G
5 Amp 5x20mm

5   A m p   3 A G
5   A m p   5x20mm
5   A m p   S l o   3 A G

PART NUMBER

CPP-102
CER-107C
CP-104A
CP-104A
CPP-333
CP-104A
CER-107C
CP-104A
CP-104A
CER-106B
CYV-104
CER-227F
CER-107C
CER-688D
CER-688D
CD-l  03/20
CD-103A

SSH-613
SSH-613
SSH-708
SSH-708
SSH-613
SSH-708
SSH-708
SSH-611
SSH-613
SSH-708
SSH-613
SSH-710
SSH-709
SSH-613
S S - 1 0 2 A

SS-140
SSH-730
SSH-730

S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
S S - 1 6 2
SS-212

SSH-652
SSH-628
HW-735G
CC-0374
CC-0373

CCH-245
CCH-246
CCH-247
CCH-233

SWH-510
SWH-0392 (Gray)
SWH-0393 (Black)
F S - 0 0 5
FS-0387 (230VAC)
F S - 0 0 5
FS-0387 (230VAC)
FS-005SB (100,120VAC)

2.5 Amp Slo 5x20mm     FS-0383 (230VAC)

Содержание 9130 series

Страница 1: ...H O M E A U D I O C O M P O N E N T S 0 W N E R S M A N U A L Series09130 P 0 W E R A M P L I F I E R ...

Страница 2: ...mount on a carpeted shelf or in a sealed enclosure Allow for proper clearance above the equipment WATER AND MOISTURE The equipment should not be used in or around water such as a bathtub sink or swimming area Also the equipment should not be used in areas prone to flooding such as a basement The equipment should be connected only to a power source of the same voltage and frequency as that listed o...

Страница 3: ...d has been spilled into the equipment or C The equipment has been exposed to rain or D The equipment does not appear to operate normally or exhibits a marked change in performance or E The equipment has been dropped or the enclosure has been damaged 15 SERVICING The user should not attempt to service the equipment beyond that which is described in the operating instructions All other service shoul...

Страница 4: ...m 7 Outputs 8 Gain Controls 8 Mono Stereo Switching 8 Soft Turn On System 8 Thermal Protection System 8 CIRCUIT HIGHLIGHTS 9 ADDITIONAL INFORMATION Loudspeaker Load Impedance Considerations 9 Changing Line Voltage Rating 10 Adjusting Bias 10 General Troubleshooting Hints 11 Ground Loops 11 Cleaning Maintenance 12 Functional Block Diagram 13 Parts List 14 Component Layout Diagram 15 Circuit Schemat...

Страница 5: ...s Power Consumption Size Weight 65 watts per channel 8 ohms less than 0 008 4 Hz to 40 kHz greater than 100 dB unweighted 22 000 ohms 1 1 volts RMS 100to1 kHz 50to10kHz Power Switch Left Right Gain Controls Mono Stereo Switch Right and Left Mono RCA jacks Right Left and Mono 5 way Binding Posts 40 watts quiescent 600 watts maximum 17 W x 9 D x 3 5 H excluding feet faceplate 17 or 19 W 43 2cm W x 2...

Страница 6: ...on is labelled directly above the power cord connector Units wired for 230VAC may be used over a range of 220 to 240VAC OPERATION CONNECTIONS POWER CORD CONNECTION POWER SWITCH INPUTS Units wired for 100 and 230 VAC are supplied without power cords Local agents will supply cords with male connectors appropriate to the local standard Units wired for 120 VAC are supplied with a detachable AC power c...

Страница 7: ...LEFT MONO GAIN POWER SWITCH UP ON DOWN O F F I 3 I RACKMOUNT HOLES RIGHT 19 VERSION ONLY GAIN 9130 AMPLIFIER FRONT PANEL VIEW ...

Страница 8: ... 7 ...

Страница 9: ...signal and the full counter clockwise position attenuates the input signal completely Most applications will dictate that these controls be set to their maximum clockwise position In situations of unusually high level signal sources or for matching levels in multiple amplifier installa tions it may be desirable to use an intermediate position of the Gain Controls Unless intentionally introducing d...

Страница 10: ... system is connected to a small transistor switch that turns off the input stage of the amplifier which effectively shuts down the entire amplifier When the heatsinks cool to a safe temperature the amplifier is turned on again The Soft Turn On Off System cooperates with the Thermal Protection System by sensing the output of the high voltage power supply At power up when both the comparator and pow...

Страница 11: ...t 100 120 VAC the AC line fuse should be a 1 4 x 1 1 4 size and approved by UL CSA For units wired at 230 VAC the fuse should be a 5 x 20mm size and approved according to IEC 127 Replace the cover Obtain a new voltage configuration label from the factory and affix over the original markings on the rear panel Alternately prepare a small self adhesive label and indicate the new voltage with permanen...

Страница 12: ...difference between two points in a ground circuit and aggravated when multiple paths for a given circuit exist Noise free audio performance is dependent upon all grounds being at the same potential with a single path for each ground connection Ground loops can exist in two forms 1 loops created in audio interconnects and 2 loops created between earth grounded chassis Mounting components to a rack ...

Страница 13: ...d systems then it is advisable to isolate the preamplifier chassis from the rack rails This may be accomplished by sandwiching a thin sheet of insulating material i e plastic washers or several layers of electrical tape etc between the rack and the preamplifier and securing the unit with non metallic i e nylon etc hardware It may be necessary to insulate other components so that only one component...

Страница 14: ...LEFT MONO INPUT LEFT MONO I MONO STEREO RIGHT INPUT LEFT OUTPUT RIGHT OUTPUT THERMAL THERMAL PROTECTION I SOFT SENSORS TURN ON OFF SYSTEM SYSTEM A 4 9130 FUNCTIONAL BLOCK DIAGRAM ...

Страница 15: ...ropylene 0 1 Polyester 100 Electrolytic 0 1 Polyester 0 1 Polyester 10 Electrolytic 0 1 Polyester 220 Electrolytic 100 Electrolytic 6800 Electrolytic 6800 Electrolytic 0 01 Ceramic 0 01 UL Approved Q1 Q101 2N5550 Q2 Q102 2N5550 Q3 Q103 2N5401 Q4 Q104 2N5401 Q5 Q105 2N5550 Q6 Q106 2N5401 Q7 Q107 2N5401 Q8 Q108 2N2222A Q9 Q109 2N5550 Q10 Q110 2N5401 Q11 Q111 2N5550 Q12 Q112 2SK1056 Q13 Q113 2SJ160 Q...

Страница 16: ...a L c4w m IL bO I L ...

Страница 17: ...Ll uTSl n cl u 1 2 5 cl u XI cl 1m I ou r l CAUTION d F O R CO NliNUED P R O T E C T I O N u AGAINST FIRE HAZARD REPLAGE ONLY WITH SAME F4 AMP TYPE AND RATING FUSES ...

Страница 18: ... i99 RIGhT C H A N N E L 201 298 COMMON PARTS 301 399 cHASsIs powER SUPPLY 4 LEFT CMNNEL ONLY SHOWN 5 STEREO MONO MilCH SHOWN IN STEREO PCStllON 6 XAGEIXINCTOR SHOWN IN 7 LINE FUSE VALUE lOO lZO Ac 5A SLO Bu 23OVACz 2 5A SLO BLO UNE FUSE SEE NOTES CR6 b lN4146 CR8 I lN4146 9 130 CIRCUIT SCHEMATIC DIAGRAM REVISED S 3 92 ...

Страница 19: ... l 9 ZN5550 R18 475 LL e 4 z lN4148 1 0 R14 R13 22 1K l lK 1 I of3 RlOq 2N2222 SK R262 7 1 1 I R21 b 221 010 2N5401 CR8 I lN414 8 1 N4 Q13 2SJl60 YI T 1 F2 V NV 5A I CIRCUIT SCHEMATIC DIAGRAM RMSEC g 3 92 TO L CH TO R CH zo4 R211 3 3K I R207 R206 I c Y T r R215 I IR208 1 ...

Страница 20: ... the date of purchase including parts labor and return shipping costs within the Continental United States Alaska and Hawaii This warranty applies only to products sold in the United States Of America For warranties outside the U S A please contact your local agent It is the owner s responsibility to pay shipping preferably United Parcel Service UPS to the factory collect shipments will not be acc...

Отзывы: