29.
505
18
Electric current
3.5 Obligations of the operator
Operator is the person who operates the access control system for commercial or
economic purposes or a allows third party for use thereof and bears the legal product
responsibility for the protection of the user, the personnel, or third parties during op-
eration.
Operator's obligations
The access control system is commonly used in the commercial sector. The opera-
tor of the access control system is therefore subject to statutory occupational safety
obligations.
In addition to the safety notes in these instructions, safety, work safety, and environ-
mental regulations valid for the area of application of the access control system must
be followed.
Here, in particular:
• The operator must ensure that escape routes and emergency exit doors are ac-
cessible for all people in case of danger.
• The operator must be aware of the applicable occupational safety regulations
and determine other hazards in a hazard assessment that may arise from the
special working conditions at the place of use of the access control system.
They must be implemented for the operation of the access control system in the
form of operating instructions.
• During the entire operating time of the access control system, the operator must
verify that the operating instructions created correspond to the current state of
the regulations and, if necessary, adapt them.
• The operator must clearly regulate and specify the responsibilities for installa-
tion, operation, troubleshooting, maintenance, and cleaning.
DANGER!
Risk of fatal injury from electrical current!
In case of contact with live parts, there is immediate danger to life by elec-
trocution.
Damage to the insulation or individual components can be dangerous to
life.
• Work on the electrical system may only be performed by trained elec-
tricians.
• In case of damage to the insulation, switch off voltage supply immedi-
ately and promptly initiate repairs.
• Before starting work on live parts of electrical systems and operating
materials, it must be ensured that the equipment is de-energised for
the duration of the work. Observe the 5 safety rules:
– Disconnect.
– Secure against reconnection.
– Ensure that there is no voltage.
– Earth and short circuit.
– Neighbouring parts that are live must be covered up or fenced off.
• Never bypass or disable fuses. The correct amperage must be used
when replacing fuses.
• Keep moisture away from live parts. It may cause short circuits.