13
H
D
E
0
3
/2
020
73
2.2
6
.6
32
5.8 Changing unit of measurement from "cm"--> "inches"
6. Troubleshooting
and fault
remedying
• Press button "S" (B) for approx. 4 seconds.
• The unit of measurement on the display changes (
see Figure 5 in picture
section
).
Lifting device will not
move
If "-" cannot be seen: check all plug-in connections
with the mains plug disconnected /
wait for 10 minutes / plug in the mains plug /
"-" illuminates again / press button S for five seconds
until a number can be seen on the control element
If "-" can be seen: check whether movement is being
blocked by an object
"E-01" displayed
Loss of position, move lifting device down and
perform a reset
Lifting device not reacting
correctly after a power
failure
Perform reset
Lifting device not moving
to the required position
Save position again
Lifting device or table
base at a slight angle
because of mechanical
effects
Rectify mechanical effects. Move lifting device
slowly downwards. Both sides are in horizontal
alignment again at the bottom position.
Press button "
" for approx. 10 seconds
Other malfunctions
Contact manufacturer (see last page for address)
or supplier
ins-src-bedieneinheit_dpt.book Seite 13 Freitag, 13. März 2020 9:56 09