EN54 APPROVED 16 - 32 ZONE CONVENTIONAL 

CONTROL PANEL

Approved Document UI-XL32-02 Issue 1.0

810a/08

Quick Start Guide

Full manual available from www.haes-systems.com

www.acornfiresecurity.com

www.acornfiresecurity.com

Содержание Excel-32 Series

Страница 1: ...ROVED 16 32 ZONE CONVENTIONAL CONTROL PANEL Approved Document UI XL32 02 Issue 1 0 810a 08 Quick Start Guide Full manual available from www haes systems com www acornfiresecurity com www acornfiresecu...

Страница 2: ...ecks as specified in BS 5839 Part 1 It is the responsibility of the system user to ensure it is regularly serviced and maintained in good working order system user to ensure it is regularly serviced a...

Страница 3: ...D PRECAUTIONS 7 GENERAL 7 SETUP PROGRAMMING 8 LEVEL 3 ENGINEERING MODE 8 LEVEL 3 ENGINEERING OPTIONS INDEX 9 OPERATING 10 PANEL CONTROLS INDICATIONS 10 DISABLE MODE 12 TEST MODE 13 FAULT DIAGNOSIS 14...

Страница 4: ...mm 130mm 410mm 465mm 450mm 400mm 450mm Fire Detection System Quiesecent and alarm current details for standby battery calculations Models Standby Current Alarm Current XL32 16 205mA 300mA XL32 24 270m...

Страница 5: ...circuits fused 500mA Conventional fire zone circuits current limit max 50mA 4K7 EOL Conventional fire zone circuits current limit max 50mA 4K7 EOL Conventional fire zone circuits current limit max 50...

Страница 6: ...ontact Clean C O Max 3A 30vdc Unfused Outputs FR fire FLT fault RS reset GD general disablement Switched ve voltage outputs for relay control Overload voltage protected to 52vdc Current limited 680R M...

Страница 7: ...s for LPCB approved panels Other equivalent batteries may be used but have not been tested for the purposes of EN54 approval Battery charging voltage 27 3 vdc nominal at 20 deg C Temperature compensat...

Страница 8: ...you are therefore requested to take such steps as are necessary to According to the provisions of the Act you are therefore requested to take such steps as are necessary to ensure that any appropriat...

Страница 9: ...egated away from mains voltage Any junction boxes used should be clearly labelled FIRE ALARM Any ancillary devices e g door retaining magnets must be powered from a separate power source Any coils or...

Страница 10: ...s 1 4 on the keypad followed by the ENTER button 1 2 3 ON P RESOUND SILENCE RESET ENTER 1 2 3 4 Disable Mode Test Mode Mute Buzzer Test Lamps To access Level 3 options first set switch 2 on the 3 way...

Страница 11: ...tector removal monitoring type for zone Schottky or Zener diode detector bases Sprinkler pump monitoring function 3121 Dependancy Mode Set panel zones to dependancy mode A B or C 2114 2124 2134 EN54 S...

Страница 12: ...e using the keypad The use of a code entry to activate the controls is enabled by default but can be disabled in the Level 3 engineering functions To activate the controls using the key switch Turn th...

Страница 13: ...1 32 N A Indicates alarm condition in zone Zone Fault Disabled Test 1 32 Indicates zone circuit is disabled or in test mode Indicates a fault in the zone circuit Supply Healthy Indicates mains and or...

Страница 14: ...button once more will move the selection back to Zone 1 again When the desired circuit outputs or delays to be disabled is indicated by a slow pulsing LED use the ENTER button to select it Once selec...

Страница 15: ...the desired zone to be tested is indicated by a slow pulsing LED use the ENTER button to select it Once selected the indicator LED will change to a rapid pulse Pressing ENTER again will toggle the zo...

Страница 16: ...Buzzer Test Lamps LED Indicator State before pressing ENTER LED Pulsing after pressing ENTER LED Steady after pressing ENTER LED Off or Slow Pulse after pressing ENTER Location Zone 1 Fire LED off Sou...

Страница 17: ...ain board is halted Fault relay is activated Repeater Comms Board System Fault LED continous and General Fault LED pulsing and Repeater Fault LED continous The Comms Board TPCA05 is halted Fault relay...

Страница 18: ...ITIALS OF TESTER TIME OF TEST SCHEDULE OF TESTING This Section To Be Used To Record ALL Weekly Tests Of The Fire Alarm System XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 16 www a...

Страница 19: ...ITIALS OF TESTER TIME OF TEST SCHEDULE OF TESTING This Section To Be Used To Record ALL Weekly Tests Of The Fire Alarm System XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 17 www a...

Страница 20: ...ITIALS OF TESTER TIME OF TEST SCHEDULE OF TESTING This Section To Be Used To Record ALL Weekly Tests Of The Fire Alarm System XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 18 www a...

Страница 21: ...ITIALS OF TESTER TIME OF TEST SCHEDULE OF TESTING This Section To Be Used To Record ALL Weekly Tests Of The Fire Alarm System XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 19 www a...

Страница 22: ...S ENGINEERS VISITS XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 20 Fault Reason For Call Out Action Taken Date Work Completed Engineer s Details www acornfiresecurity com www acor...

Страница 23: ...S ENGINEERS VISITS XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 21 Fault Reason For Call Out Action Taken Date Work Completed Engineer s Details www acornfiresecurity com www acor...

Страница 24: ...S ENGINEERS VISITS XL32 Quick Start Guide Approved Document Ref UI XL32 02 Issue 1 0 22 Fault Reason For Call Out Action Taken Date Work Completed Engineer s Details www acornfiresecurity com www acor...

Страница 25: ...t has caused the alarm A detector will have a red In the event of a false alarm look for the device that has caused the alarm A detector will have a red LED lit or check to see if a call point glass i...

Страница 26: ...www acornfiresecurity com www acornfiresecurity com...