hadewe Auroria 2 Скачать руководство пользователя страница 1

Art. 0986 
FB 04-431 Rev. 1 
Date: 04.12.2023

 

 

 
 
 
 
 
 
 

Manual 

 
 
 

 

 

 

 

Auroria 2 

 

 

 

Содержание Auroria 2

Страница 1: ...Art 0986 FB 04 431 Rev 1 Date 04 12 2023 Manual Auroria 2...

Страница 2: ...Steps 13 Working Positioning 14 Suction 16 Exchange Micro Filter 16 Exchange Control Unit Filter 16 Clamping the Bur Tool 17 Setting up the Speed 17 Memory Buttons m1 m2 m3 17 Button on the Handpiece...

Страница 3: ...else please include this document as it includes important in formation on how to correctly use the product Short description of functions The Auroria 2 is a device for the treatment of callus and na...

Страница 4: ...accessible The power switch should also always be easily ac cessible Only switch on the unit if the handpiece rests se cured in the handpiece holder or if you hold it safely in your hand Prevent any l...

Страница 5: ...dis posable gloves and protective glasses when op erating this unit In addition a face mask con forming to EN 14683 type IIR or EN 149 FFP 2 must also be worn Ensure that the patient s foot and the ha...

Страница 6: ...e that the bur tool sits firmly in the chuck do not work with tools which have an oily shaft are worn are bent Before using the equipment assure that the tool can be pushed far enough into the chuck t...

Страница 7: ...ith the suction turned on Only use the suction function if you have in stalled the suction filter Check this filter every 10 operating hours If it is full please exchange it A filter should be exchang...

Страница 8: ...t is plugged into the socket since some components are under electric volt age Any unauthorized or improper handling e g trying to repair the unit of the equipment will immediately nullify the guarant...

Страница 9: ...ter every treatment please carry out the following steps Remove the rotating tool e g bur capper etc first Then han dle the tool according to the instructions of its manufacturer Remove tissue remains...

Страница 10: ...ge of the filter bag etc 8 menu button down and reducing the suction level 9 menu button up and increasing the suction level 10 menu button OK 11 menu button stop 12 memory button m1 for speed suction...

Страница 11: ...ng scopes foot care milling trimming and pol ishing manicure grinding milling and pol ishing works The devise is determined of operating rotating instru ments which will not penetrate the skin or murc...

Страница 12: ...d Language will appear on the display Use the buttons and to select a language and press OK to confirm On the display will appear Press OK By pressing the OK button the counter which calculates the ti...

Страница 13: ...le the dust ob scures your field of vision when working clockwise Using buttons 8 and 9 you can adjust the intensity of the suction Frequently used rotation speeds and suction power settings can be sa...

Страница 14: ...14 Use Work Positioning The following images are examples of how to work on various parts of the foot Always make sure that the foot is firmly gripped and that you can work freely and without strain...

Страница 15: ...15 Use...

Страница 16: ...rate the unit with a suction filter assembled Control the bag af ter every 10 operating hours Ex change a full filter bag immediately A filter should be exchanged at least after 50 operating hours At...

Страница 17: ...unit Switch on the unit with button 16 Now you can also set the speed with buttons 3 and 4 Choose the direction of rotation with button 5 Memory Buttons m1 m2 m3 Frequently used speed or suction level...

Страница 18: ...r By pressing the OK button you will access the selective list for settings of the device With the buttons and you can go through the list and se lect a setting by pressing OK With C you can stop a fu...

Страница 19: ...with the button OK With the button and you can set the hours With the buttons and you can set the minutes Press OK to save the setting Setting the date Select from the list date Confirm with OK With...

Страница 20: ...iod between the last mainte nance and shows a recommenda tion for a new service Please con tact your distributor or an authorized repair service when this occurs In the display appears Maintenance rec...

Страница 21: ...push the but ton forward Set the screw spanner wrench on the axle and hold it tight Now use the front of the second spanner to unscrew the chuck To assemble the chuck follow the steps in reverse order...

Страница 22: ...here should be only a very thin film of oil left on the chuck Please act according to the saying Less is more Maintenance Overview What has to be done How often Done by whom cleaning the chuck monthly...

Страница 23: ...of the handpiece in form of rust bloom and causes pitting Therefore when you not working with the handpiece always remove the bur tool from it Always make sure that you do not let the handpiece fall...

Страница 24: ...ved easily Chuck is dirty Clean the chuck according to the instructions in the manual Rubber under the knob is tilted Turn rubber about 90 Unit does not work at all Check if the main switch of the uni...

Страница 25: ...to 95 not condensed Air pressure 500 hPa to 1060 hPa Operating Time The device is designed for extended usage Accessories Spare Parts art no 5179 micro filter 3752 filter 0970 foot switch 6158 cleani...

Страница 26: ...WEEE Reg No DE20392713 b2b device For disposal of this unit out of Germany please contact the site where you bought this hadewe product Note for the disposal of the device treatment system Wear protec...

Страница 27: ...tton standby no disconnection from main power supply START STOP button light ON OFF button enter menu confirm with OK C go back in menu cancel change direction suction m1 m2 m3 memory buttons for spee...

Страница 28: ...hadewe GmbH Grambartstra e 10 30165 Hannover Germany info hadewe de www hadewe de...