HADEF 62/05 S Скачать руководство пользователя страница 9

 

 

 

 

5.52.420.00.01.09 

 

 

 

As  an  option  the  device  can  be  supplied  with  an  electronic  overload  control  combined  with  a  low  voltage 
control. 

 

   

WARNING!

 

  Never exceed the nominal load! 

  It is prohibited to use the emergency stop as operational limit switch. 

 

 

  

NOTICE!

 

If it is necessary to approach the end stops during operation operating limit switches can be supplied (as an 
option). These can, however, only be used with low voltage control. 

 

 

  Load chain 

Special  quality  load  chain.  As  the  individual  components  of  the  chain  drive  are  matched  precisely  to  each 
other, only original chains may be used. 

 

 

  Load hook 

The load hook, which is made of highly stable forged steel, has a ball bearing. This facilitates attaching the 
load  and avoids the chain turning. The safety catch on  the hook prevents  the load  from slipping out of the 
hook unintentionally. The safety catch of the load hook must be able to move freely and be self-closing. 

  Chain container 

The chain container is made of unbreakable plastic, plastic-coated fabric or sheet steel. It will supply different 
sizes for different chain lengths. 

  Control 

The electrical chain hoists are controlled as standard as follows: 

By direct control  

By low voltage control, optionally. 

A remote control is available as an option. 

  Control switch 

▫  Control switch suitable for single hand use.  
▫  The control switch housing is made of shock- and fracture-proof plastic. 
▫  The control cable is fitted with a stress-relief rope (not applicable for radio control). 
▫  Plug-in connection for the control switch 

 

  Phase sequence- phase failure monitoring relay 

All devices with low voltage control are equipped with a phase sequence and phase failure monitoring relay 
as  a  standard.  This  will  prevent  incorrect  phase  sequence  when  connecting  to  the  mains  supply  and  will 
switch  off  the  device  if  phase  failure  occurs.  In  addition,  all  devices  with  low  voltage  control  are  equipped 
with thermal sensors to protect the lifting motor and end switches for lifting/lowering as a standard.  

 

Technical data 

 

 

 

Capacity

 

Type 

kg 

125 

250 

250 

500 

1000 

1000 

2000 

Chain falls 

 

 

Duty classification  

FEM 9.511/ISO 4301 

 

 

2m/M5 

1Am/M4 

1Am/M4 

1Am/M4 

1Am/M4 

1Bm/M3 

1Am/M4 

Chain dimensions 

 

mm 

5x15 

5x15 

5x15 

5x15 

5x15 

7x21 

7x21 

Lifting speed 

 

m/min 

8/2 

8/2 

16/4 

8/2 

4/1 

10/2,5 

5/1,25 

Motor power

 

 

kW 

0,18/0,05 

0,36/0,09 

0,75/0,18 

0,75/0,18 

0,75/0,18 

1,9/0,45 

1,9/0,45 

Operating time ED 

 

100 

60 

100 

40 

40 

30 

30 

Starting current 

 

2,5/0,64 

4,7/1,15 

9/1,7 

9/1,7 

9/1,7 

21/4,5 

21/4,5 

Nominal current 

 

0,6/0,36 

1,1/0,6 

2,1/0,95 

2,1/0,95 

2,1/0,95 

4,5/2,3 

4,5/2,3 

Starting - Cos 

f

 

 

 

0,88/0,8 

0,88/0,8 

0,88/0,8 

0,88/0,8 

0,88/0,8 

0,88/0,8 

0,88/0,8 

Noise emission* 

 

db(A) 

72 

72 

72 

72 

72 

78 

78 

Weight ** 

kg 

30 

30 

33 

33 

33 

54 

54 

kg 

37 

37 

40 

40 

47 

68 

75 

kg 

44 

44 

47 

47 

54 

75 

93 

kg 

62 

62 

65 

65 

65 

83 

103 

Weight per m add. lift 

 

kg 

0,54 

0,54 

0,54 

0,54 

1,08 

1,1 

2,2 

Hand chain pull ~ 

30 

40 

40 

40 

80 

80 

125 

Travel speed 

m/min 

16/4 

16/4 

16/4 

16/4 

16/4 

16/4 

16/4 

Travel motor power 

kW 

0,25/0,06 

0,25/0,06 

0,25/0,06 

0,25/0,06 

0,25/0,06 

0,25/0,06 

0,25/0,06 

Travel speed 

m/min 

30/7,5 

30/7,5 

30/7,5 

30/7,5 

30/7,5 

30/7,5 

30/7,5 

Travel motor power 

kW 

0,5/0,12 

0,5/0,12 

0,5/0,12 

0,5/0,12 

0,5/0,12 

0,5/0,12 

0,5/0,12 

Wheel pressure max. *** 

 

kN 

0,8 

1,4 

2,6 

2,6 

3,4 

5,1 

6,8 

Beam flange width 1N 

mm 

64-152 

64-152 

64-152 

64-152 

64-190 

64-190 

88-190 

H+E 

mm 

50-179 

50-179 

50-179 

50-179 

50-179 

50-179 

66-185 

Beam flange width 2N 

mm 

153-310 

153-310 

153-310 

153-310 

191-310 

191-310 

191-310 

H+E 

mm 

180-310 

180-310 

180-310 

180-310 

180-310 

180-310 

186-310 

*) 1m distance, tol2dB(A)     **)at 3m suspension or track height    ***) Wheel pressure including the weight of hoist device and trolley at nominal load at 3m suspension height. 
Chains acc. special quality acc. Thechical requirements as EN818-7-T 

 

Содержание 62/05 S

Страница 1: ...Electric Chain Hoist 62 05 stationary with suspension eye or hook S with monorail push travel trolley R with monorail hand geared trolley H with monorail electric trolley E Installation Operating and...

Страница 2: ...e life 4 2 Safety 4 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 5 2 4 Appropriate use 5 2 5 Basic safety measures 6 3 Transport and St...

Страница 3: ...ucts meet European Union requirements in particular the valided EU Machine Directive The entire company works acc to a certified quality assurance system as per ISO 9001 The production of components a...

Страница 4: ...GER Failure to follow the instructions of this manual can lead to unpredictable hazards For any resulting damage or personal injury HADEF assumes no liability The unit was designed and built following...

Страница 5: ...ntenance work DANGER In order to avoid severe injury please pay attention to the following when using the equipment Use protective clothes equipment Do not wear long hair hanging down open Do not wear...

Страница 6: ...onsible supervisor immediately If the unit is put into motion any persons in the immediate vicinity must be informed by calling to them Please pay attention to the regulations for load carrying device...

Страница 7: ...n parking position If the device is set up in a continuously humid environment with strong temperature fluctuations the correct functionings are endangered by the forming of condensation During longer...

Страница 8: ...on against functional failures in case of extreme environmental impact is the regular use of the equipment If the hoist is not used very often we recommend to carry out a test run at least once a week...

Страница 9: ...ff the device if phase failure occurs In addition all devices with low voltage control are equipped with thermal sensors to protect the lifting motor and end switches for lifting lowering as a standar...

Страница 10: ...om the outer to the inner side X increases or from the inner to the outer side X decreases Washers 6 and rubber discs depended on type leave a distance for the load hook It is important that the load...

Страница 11: ...lief cable 4 Connector plug 5 Locking clips Unscrew the locking screw 1 incl the retaining plate 2 Screw the strain relief cable 3 behind the retaining plate 2 tightly to the casing with the locking s...

Страница 12: ...n 8 System start optional Illustration 9 Push button functions E Relieved push button stand still push button half pushed slow speed push button pushed completely fast speed Illustration 10 Red Emerge...

Страница 13: ...ecifications in the test book During operation the nominal load of the unit must not be exceeded 9 Commissioning 9 1 General The operator of the unit is responsible for the entire system According to...

Страница 14: ...ial number 9 2 5 Assignment recommendation of line cross sections and fuses Assignment of line cross sections and fuses must be done acc to VDE0100 For total motor output add all motor output data The...

Страница 15: ...for lifting If desired the chain hoist can be fitted with a limit switch for lifting GTES 51 67 or GTES 51 180 It allows to adjust any switching point desired for example the limit positions of upper...

Страница 16: ...service initially or when putting back into service it must be checked whether All fastening screws if existent socket pins flap socket and safety devices are tightened and secured The oil levels in t...

Страница 17: ...and when the conditions for replacement are reached i e one or several dimensions in the table have been reached there is corrosion or elongation the chain must be replaced When replacing the chain al...

Страница 18: ...ain Tightening torque of screws for bottom block M5 10 9 8Nm M6 10 9 15 Nm Illustration 15 2 fall version 2 1 put the chain through the bottom block more and more fix the last chain link with bolt 4 a...

Страница 19: ...anchor plate 10 using a feeler gauge until nominal air gap a is reached see table 4 Unscrew the cap screws 8 from the magnetic body clockwise 5 Tighten the locking screws 6 6 Check the air gap again...

Страница 20: ...These conditions have to be written down in the test book The owner user is responsible to make sure that these conditions are observed 13 2 Periodic checks Independently from the regulations of the i...

Страница 21: ...or deformation the chain must be replaced 13 4 Checking the load hook Load hook X measuring distance hook mouth width Y measured length from hook no 6 H thickness of hook saddle Illustration 23 Dimen...

Страница 22: ...tal influences that foster wear such as sand a dry lubricant should be used e g graphite powder When lubricating the chain s condition of wear should be checked CAUTION Do not use grease for lubricati...

Страница 23: ...6 320 Renolin PG 460 Omala S4 WE 460 Glygolube 460 Degol GS 460 Glygoyle 460 Alphasyn PG 460 Kl bersynth GH 6 460 Renolit FEP2 Alvania EP2 Unirex EP2 Mobilux EP2 MULTIS EP2 Renolin B10 VG32 Tellus Oi...

Страница 24: ...manufactuerer for repair Rotor is rubbing Brake does not release See problem Brake does not release Defect of capacitor only for alternating current 1 Replace the capacitor Defect of starter relay on...

Страница 25: ...all operating material is disposed of in accordance with environmental regulations 17 1 Temporary decommissioning Measures are as above Also read the chapter Transport and storage 17 2 Final decommiss...

Отзывы: