4.
Click the check boxes for Space delimiter and Treat consecutive
delimiters as one. Click
NEXT
.
5.
Select General as the column data format, then click
FINISH
.
6.
In the Import Data window, select Existing worksheet. Select the
starting cell, then click
OK
. The data will appear in the spreadsheet.
6.4 Data format
The example shows the channel number, start date, start time and the
format of the downloaded data. BOD values in mg/L follow. Only the first
data points of a maximum of 360 equal distance points are shown. Each
line ends with a carriage return and a line feed. The end of the data
stream is shown by a message such as "Test Run to Completion" and a
dollar symbol ($).
If small negative BOD values are seen at the start of a test, refer to
on page 10.
Example of the data format
BOD Log for Ch 1
Status: END
Full Scale: 700 mg/L
Tst length: 7 days
Start Date: 3/3/08
Time: 13:04
Days, Reading (mg/L)
0.00, 0
0.05, 10
0.11, 12
0.16, 12
0.22, 14
0.27, 14
0.33, 12
0.38, 8
0.44, 10
0.50, 12
0.55, 12
0.61, 14
-
-
-
Test Run to Completion
$
6.5 Print test results
The BODTrak II is applicable to use with the Citizen PD-24 printer.
1.
Connect the printer cable to the serial I/O port on the instrument. Use
the gender adapter supplied with the printer to make the connection.
Make sure that the printer settings are correct (
on page 6).
2.
Power on the instrument.
3.
Push and hold the applicable channel number for approximately
5 seconds at any time during a test.
The test results move from the instrument to the printer. The
instrument sends a copy of the graphical display and a truncated
data stream (127 data points).
Section 7 Maintenance
D A N G E R
Multiple hazards. Only qualified personnel must conduct the tasks
described in this section of the document.
English
9
Содержание BODTrak II
Страница 110: ...15 15 1 2 15 1 2 3 4 5 2 6 mg L 360 2 7 BODTrak II UL CSA 115 VAC NEMA 5 15P 110...
Страница 112: ...9600 3 3 1 6 1 2 112 4 2 2 1 4 2 5 3 1 4 1 2 112 3 3 1 0 99 2 1 12 3 1 31 1 112...
Страница 116: ...RS232 111 2 3 5 127 7 MSDS SDS 7 1 7 2 8 8 1 4 10 113 116...
Страница 117: ...4 1 4 20 C 2 5 3 8 2 4 117 350 mg L 160 mL 1 GGA Hatch Hatch 0 68 0 70 mg L 0 700 mg L 700 mg L 8 3 4 117 2 5 Hach 117...
Страница 156: ...2 1 CD 2 2 2 3 2 4 2 5 ICES 003 A 156...
Страница 159: ...9600 baud 3 3 1 6 1 2 159 4 2 2 1 4 2 5 3 ON OFF 1 4 1 2 159 3 3 1 0 99 2 1 12 1 ON OFF 159...
Страница 163: ...RS232 158 2 3 5 127 7 MSDS SDS 7 1 Cleaning 7 2 8 8 1 BOD 4 BOD 10 160 163...
Страница 167: ......