WARNINGS & SAFETY INSTRUCTIONS

Habonim cannot anticipate all of the situations a user may encounter while installing and using Habonim valves. The user 

MUST

 

know and follow all applicable industry specifications on the safe installation and use of these valves.  Misapplication of the 
product may result in injuries or property damage. Refer to Habonim product catalogues, product brochures and installation, 
operating and maintenance manuals for additional product safety information or contact Habonim.   

1. 

Keep hands and objects away from the valve ports at all times. Actuated valves could be accidentally operated, resulting in 
serious injury or valve damage.

2. 

Before removing a valve from the line, always make sure the line has been depressurized and drained. Cycle the valve a few 
times to relieve any pressure that could be trapped in the body cavity.  

3. 

Utmost caution must be taken when handling a valve that has toxic, corrosive, flammable or a contaminant nature media 
flowing through its pipeline. The following safety precautions are recommended when dismantling valves with hazardous 
media:

a. 

Wear eye shield, protective headgear, clothing, gloves and footwear.

b. 

Have available running water.

c. 

Have a suitable fire extinguisher when media is flammable.

4. 

Do not try to operate a valve that exhibits any sign of leakage. Isolate the valve and either repair or replace it.

5. 

Do not use or substitute non Habonim components or parts in Habonim valves and assemblies.

1. GENERAL

This Installation, Operating & Maintenance manual present the instructions required for safe use of Habonim 2-piece High Pressure, 
reduced bore ball valves type H24 series. Before using any of these valves, read the entire IOM carefully and make sure you understand 
everything. Where in doubt, please consult with Habonim engineering team.             

Inspired By Challenge

Habonim ISRAEL

Tel: +972-4-6914911 / 6914903

Fax: +972-4-6914935

[email protected]

Habonim USA

Toll Free Phone: 1-866-261-8400

Toll Free Fax: 1-866-243-9959

[email protected]

Habonim China

Tel: + 86 21 64453190 *146

Fax: + 86 21 64453191

[email protected]

Habonim UK

Tel: +44-1633-484554

Fax: +44-1633-482252

[email protected]

Habonim Australia

Tel: +61 3 9556 5428

[email protected]

I-H24-12/15

Содержание AFH24

Страница 1: ...aminant nature media flowing through its pipeline The following safety precautions are recommended when dismantling valves with hazardous media a Wear eye shield protective headgear clothing gloves and footwear b Have available running water c Have a suitable fire extinguisher when media is flammable 4 Do not try to operate a valve that exhibits any sign of leakage Isolate the valve and either rep...

Страница 2: ...s can be used in is large it is not possible to cover all installation and maintenance instructions for service of the valves It is the user s responsibility to use the valves as recommended and in accordance with the pressure and temperature limits as stated in this manual Where in doubt please consult with Habonim Any unstable fluid or gas should be identified by its manufacturer and must not be...

Страница 3: ...1 2 Remove any special packing materials which were used for packing 7 1 3 Check the valve for any flow direction indication marks Appropriate care must be taken to install the valve for proper flow orientation 7 1 4 Inspect the valve interior through the end ports to determine it is clean and free from foreign matter according to ASME G93 03E1 7 1 5 Cycle the valve and inspect any functionally si...

Страница 4: ... with the threaded side first and carefully guide it up through the stem bore 10 4 Holding the stem up insert the new packing over the stem and into the stem bore Place the follower and two disk springs face to face onto the stem 10 5 Thread the stem nut onto the stem Tighten the stem nut to the torque figures table 1 10 6 Place the locking clip on the stem nut by adjusting the orientation of the ...

Страница 5: ...in all trapped media from the valve cavity FIGURE 2 Valve swing out position and maintenance BODY BALL SEAT PRES SIZE Habonim logo Body material Seat material Valve size Valve description Ball material Work order Max pressure Step 1 Slide out and center Section maintenance Step 2 Stem maintenance INDUSTRIAL VALVES ACTUATORS LTD KFAR HANASSI 1230500 IL BODY BALL SEAT BAR C 1155 Habonim logo Body ma...

Страница 6: ...479 316 316L B473 N08020 B164 N04400 B574 N06022 B574 N10276 A479 S31254 A479 S31803 A479 S32750 B637 UNS N07718 Inconel 718 1 4 Stem A564 Gr 630 H1150D 17 4PH B164 N04400 B574 N06022 A479 S31803 A479 S32750 B637 UNS N07718 Inconel 718 1 5 Seat PVDF DELRIN PEEK CF PEEK PCTFE KEL F 2 6 Body seal PTFE Graphite NBR Viton 1 7 Stem thrust seal PEEK CF PEEK PCTFE KEL F TFM 2 CF PTFE 2 1 7a Anti abrasion...

Отзывы: