Smarter Control Solutions.

Содержание HTE-01

Страница 1: ...Programming Guide Smarter Control Solutions...

Страница 2: ...ndicates a condition which may cause severe personal injury death or major property damage Important Information Indicates information which requires special attention for correct operation of the con...

Страница 3: ...01 Base Module s Daylight Savings Time Date Time Settings Emergency Heat Setting HTE 01 Thermostat Schedule Setup HTE 01 Thermostat Administrative Parameters Unpair Modules Enable Auto Changeover Butt...

Страница 4: ...1 Home Screen Display 1 2 3 4 5 6 7 9 10 11 12 13 14 8...

Страница 5: ...dicator status only shown when on battery power used Full Half Low Replace 10 Schedule running indicator Schedule Schedule running1 Blank No Schedule 4 System type 11 Set point 5 Room temperature 12 C...

Страница 6: ...3 HTE 01 Thermostat Controls 1 2 3 4 5 Front View Bottom Side View...

Страница 7: ...maintained until the Next schedule period Set point is changed to the scheduled value Mode button is held for 3 seconds displaying Schedule Perm Override To change the temperature units between F and...

Страница 8: ...k Smoke or CO2 accompanied by descriptive text on the thermostat display Flashing Red Identify Mode Base module is in identify mode initiated by the thermostat or web application Alternating Green Red...

Страница 9: ...12 Date Set Date Set Date 1 to 31 Year Set Year Set Year Hour Set Hour Set Hour 12 am to 12 pm Minute Set Minute Set Minute 1 to 59 Emergency Heat Enable Disable Toggle Emergency Heat y or n Schedule...

Страница 10: ...l flashes indicating all mod ules Press to scroll through the list of connected base modules If any module has been paired but has lost its link to the Thermostat the pair ing status indicator will bl...

Страница 11: ...The LED on the module corresponding to the ID selected will begin flash ing red for 10 minutes If All is selected the LEDs on all connected modules will flash red To exit ID mode press hold the Mode a...

Страница 12: ...ay shows the number of base modules currently paired Use the button to begin a 10 minute count down to pair addi tional base modules Press the PAIR button on each base module to be added The LED will...

Страница 13: ...odules will flash on the display The pairing sequence will time out after 10 minutes To exit the parameters menu press hold Mode and Fan until a sound is emitted The Habitat HTE 01 Thermostat will sup...

Страница 14: ...buttons to set the month Press Fan to continue Use buttons to set the date Press Fan to continue Use buttons to set the year Press Fan to continue Use buttons to set hour Press Fan to continue Use bu...

Страница 15: ...base modules currently paired Press Mode to scroll back to the Schedule Param eter and use the button to toggle schedule to Y Press Fan to confirm Emergency Heat Setting Schedule Setup Use buttons to...

Страница 16: ...or Weekend SS MF Set periods SS Set periods Same schedule throughout the week Set periods Different schedule each day MO TU WE TH FR SA SU Set periods Use buttons to set the minutes for the first per...

Страница 17: ...day or group of days can be programmed After the 6th period is programmed the HTE 01 Thermostat will move to the next day or group depending on the sched ule type Once all periods and day groups have...

Страница 18: ...d 10 seconds and is displayed Use the buttons to change to Use the Fan button to scroll forward and the Mode button to scroll Parameter Display Description Unpair Modules Use the buttons to change fro...

Страница 19: ...Button Press Sound Use the buttons to toggle between y to n then press Fan Pressing n will silence buttons This does not affect the feedback beeps for entering the Param eters Administrative Paramete...

Страница 20: ...ccept If this value is changed the current set point schedule set point min max setpoint or freeze protection setpoint may be altered automatically to accommodate the change Range 2 F to 6 F 1 C to 3...

Страница 21: ...epancy between the sensor reading and actual temperature if it exists Press Fan to accept and go to the next parameter Range 6 F to 6 F 3 C to 3 C Increment 0 5 F 0 25 C Freeze Protection Use the butt...

Страница 22: ...45 F to 89 F 7 C to 31 5 C Increment 1 F 0 5 C Minimum Set Point Cooling Use the buttons to set the minimum temperature set point for cooling Press Fan to accept and go to the next parameter The maxi...

Страница 23: ...ll base modules Note If the thermostat is powered by batteries only shorter periods will decrease battery life Range 1 to 5 minutes Default 1 minute Increment 1 minute Factory Reset Use the buttons to...

Страница 24: ...Designed and Engineered in New York U S Registered Trademark Patents pending www habitattechnologies com Internal use HC PG HTE 01 HTM 01 2020 06 v1 Smarter Control Solutions...