User Guide
TGT. 27.09.2017
Technical
Page 19 of 21
©Copyright by Habegger Maschinenfabrik AG
Version 01 / 27.09.2017
6
Faults
Faults
possible causes
Procedures
Motor will not start when button is
pressed
Cover is missing or not screwed on
Power cable not plugged in
Extension cable not connected
Rope shaft not swivelled in
Extension cable broken
Fuse in the supply has blown
Emergency stop button on pendant
station pressed
Hook touching housing and
Limit switch pressed
other causes
Replace cover and screw on
Insert plug
Connect cable
Swivel rope shaft inwards until latch
clicks
Replace cable
Clarify cause, secure
Replace
Unscrew button
Press the “Lower” key and the over-
ride button on the control box
Call an electrician, diagram is
in control cabinet
The motor is not moving despite
making noise
Broken rectifier, holding brake will not
release
Pull on cable is greater than permitted
tensile force
Replace rectifier
Reduce load or employ pulley block
pulling system
Rope is not moving despite driving
wheel turning
Rocker not swivelled in
Rope incorrectly inserted
too small or too thin rope
inserted
Cable severely worn out
Driving wheel or rope too heavily
greased
Groove in driving wheel heavily soiled
no load on rope
Swivel rocker inwards
Insert rope according to diagram
Insert correct rope
Insert new rope
clean
clean
Load rope