81
UTD.123.2019-10.00_EN
16 - E series - Mounting positions, oil quantity and position of plugs
For inclined mounting positions, when "spec." is stated on nameplate in IM field, refer to the attached
specific documentation.
16.1 - Oil level (quantity) for coaxial GEAR REDUCERS and GEARMOTORS sizes 50 ... 81
(E series) supplied FILLED WITH OIL
Before commissioning of the units verify that the dimensions X [mm] between the
plug shoulder and oil
level
corresponds to the value stated in table 14.1, using a dipstick.
Before checking ensure that there are no more gas pockets in the oil which is included in the gear reducer.
Measure as specified in fig. 14.1.1 with gear reducer in mounting position B6.
Fig.
14.1.1
-
Position the gear reducer or gearmotor,
mounting position B6 for the measurement of oil
level (quantity).
Tab. 14.1.1 - Oil level (dimension x) and oil quantity gear reducers and gearmotors E series sizes 50 ... 81
Size
Train of gears
Mounting position
Oil level (dimension x
1)
) [mm] and quantity [l]
2I
3I
B3
B6, B7, B8, V6
V5
B3, V5, V6
B6, B7
B8
mm
l
mm
l
mm
l
mm
l
mm
l
mm
l
50, 51
65
0.8
50
1.1
35
1.4
60
0.8
45
1.1
30
1.4
63, 64
120
1.6
90
2.2
60
2.8
115
1.6
85
2.2
55
2.8
80, 81
110
3.1
75
4.3
45
5.5
105
3.1
70
4.3
40
5.5
1) Tolerance of dimension x:
±
5 mm.