116
UTD.123.2019-10.00_EN
Troubles: causes and corrective actions
If deviations from normal operation occur, refer to the following table. If deviations persist, consult Rossi.
Trouble
Possible cause
Corrective action
Oil leakage from seals
Seal stiffening due to long lasting
storage
Clean the area and check the leakage
after some hours of running
Seal damage or wear
Consult Rossi
Multiple disc brake does not block
Residual pressure in the circuit
Verify the hydraulic circuit
Worn discs
Consult Rossi
With running motor, gear reducer
does not operate
Possible brake blocked
Verify hydraulic braking circuit
Excessive overheating
No lubricating oil
Add lubricating oil
Disc brake does not open correctly
Verify pressure when brake opening
Multiple disc brake does not release
No pressure at brake
Verify brake connection
Defect brake seals
Consult Rossi
Excessive vibrations
Internal trouble
Consult Rossi
Excessive noise level
Internal trouble
Consult Rossi