7
USER MANUAL
PURE SINE WAVE INVERTER 300W-600W
NOTICE!!!
Inverter’s ON/OFF switch and
remote control´s ON/OFF switch is connected in
parallel. To use this remote control, you have to switch OFF the remote control and also
the inverter. Otherwise, the remote control will not work properly.
4.
FITTING THE INVERTER.
4.1
MOUNTING REQUIREMENTS.
When selecting the installation location, observe the following instructions.
The inverter can be mounted horizontally or vertically.
The inverter must be installed in a place that is protected from moisture.
The inverter may not be installed in the presence of flammable materials.
The inverter may not be installed in a dusty environment.
The place of installation must be well ventilated. A ventilation system must be
available for installations in small, enclosed spaces. The minimum clearance
around the inverter must be at least 20 cm (fig. 1).
The air intake on the underside or the air outlet on the back of the inverter must
remain clear.
For ambient temperatures higher than 50 °C (such as in engine or heating
compartments, or direct sunlight), the heat from the inverter under load can lead
to automatic shutdown.
The device must be installed on a level and sufficiently sturdy surface.
Fig. 1