3.

 

TECHNICAL DESCRIPTION. 

The inverter can be operated wherever a 12V DC connection is available. The light weight, 
compact construction and E mark certification of this device makes the inverter ideal to use 
in motorhomes, campers and yachts. 
 
The output voltage corresponds to the household voltage from the socket (pure sine wave, 
THD < 3 %). 
 
The inverter has various protective mechanisms: 

 

Overvoltage shutdown: the inverter shuts itself off when the voltage exceeds the 
cut-off value. It restarts automatically once the voltage returns to the normal 
values. 

 

Undervoltage shutdown: the inverter shuts itself off when the voltage sinks the 
cut-off value. It restarts automatically once the voltage rises to the normal 
values. 

 

Exceed temperature shutdown: the inverter shuts itself off when the 
temperature inside the device or the temperature on the cooling element 
exceeds the cut-off value. It restarts automatically when the temperature returns 
to the normal values. 

 

Overload protection: the inverter shuts itself off when the AC load connected to 
the inverter output exceeds the cut-off value. It restarts itself once the load 
connected to the inverter output returns to the normal values. 

 

Short circuit protection: the inverter include an internal fuses to prevent any 
damage in the 12V DC circuit if there is a short circuit.  

The inverter can be easily operated using a remote control (not included). 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 36191280

Страница 1: ...IONS 5 3 1 REMOTE CONTROL Art 4403445 6 4 FITTING THE INVERTER 7 4 1 MOUNTING INSTRUCTIONS 7 4 2 MOUNTING THE INVERTER 8 5 CONNECTING THE INVERTER 8 5 1 GENERAL INSTRUCTIONS 8 5 2 WIRING DIAGRAM 9 5 3...

Страница 2: ...fied workers who are familiar with the risks involved and the relevant regulations People including children whose physical sensory or mental capacities or whose lack of experience or knowledge preven...

Страница 3: ...www haba nl info haba nl 3 USER MANUAL PURE SINE WAVE INVERTER 300W 600W 2 SCOPE OF DELIVERY The set include 1 Pure sine wave inverter 2 Earth cable 3 Battery cables 1 2 3...

Страница 4: ...tage shutdown the inverter shuts itself off when the voltage sinks the cut off value It restarts automatically once the voltage rises to the normal values Exceed temperature shutdown the inverter shut...

Страница 5: ...ROL ELEMENTS AND CONNECTIONS The inverter has the following connections and control elements on the left side No Description 1 230V AC output socket 2 Remote control socket 3 ON OFF switch 4 USB socke...

Страница 6: ...C input negative pole 3 1 REMOTE CONTROL Art 4403445 NOT INCLUDED No Description 1 ON OFF switch 2 Battery capacity 5 levels 20 40 60 80 100 3 Load level 5 levels 20 40 60 80 100 4 ON OFF indication L...

Страница 7: ...n a place that is protected from moisture The inverter may not be installed in the presence of flammable materials The inverter may not be installed in a dusty environment The place of installation mu...

Страница 8: ...sis or earth Never use the inverter on vehicles where the positive terminal of the battery is connected to the chassis When setting up a socket distribution circuit mains setup comply with the applica...

Страница 9: ...al and fasten it with the bolt d Connect the negative cable to the black negative terminal fig 3 e Lay the positive cable from the inverter to the positive terminal of the vehicle battery and connect...

Страница 10: ...low voltage protection When DC input voltage is below 10 5 0 5 V DC buzzer sounds 2 times which indicates DC power supply voltage is decreasing and batteries need to be charged When input voltage reac...

Страница 11: ...n the inner temperature exceed the 75 degrees buzzer sounds 5 times and red light turn on AC output will automatically shut off The inverter will on automatically once the temperature returns to the n...

Страница 12: ...g yes yes Overheat protection 75 C shut off under 75 C recovery 75 C shut off under 75 C recovery Overload protection 110 120 rated power shut down 110 120 rated power shut down Low voltage protection...