1
Install the muffler [1] on the top air cylinder port
[2].
2
Install the replacement pallet-pool lifter solenoid
valve assembly from the kit [1] to the bottom air
cylinder port [2].
3
Connect the main air-tube [1] to the replacement
pallet-pool lifter solenoid valve assembly [2].
4
Connect cable 36-0675 [1] to cable 250 [2].
5
Change
Parameter 747
PAL POOL LFT DN DWL
to 3000 [1].
Reinstall the slider casting plate and cable carrier.
Pallet-Pool Lifter Solenoid Valve Assembly - Replacement - EC-400PP - AD0149