7
Cooling system
The WX3010E wireless switch adopts left to right airflow for heat
dissipation. To guarantee the performance of this cooling system, you
must consider the ventilation design for the installation site.
Figure 3
Airflow through the WX3010E chassis
•
Ensure an adequate clearance around the air intake vents and exhaust
vents. A clearance of more than 10 cm (3.94 in) is recommended.
•
Make sure the rack is well ventilated.
ESD prevention
To prevent electrostatic discharge (ESD), note the following guidelines:
•
Make sure that the wireless switch and the rack are well grounded.
•
Take dust-proof measures for the equipment room.
•
Maintain the humidity and temperature at a proper level.
•
Always wear an ESD-preventive wrist strap and make sure the wrist strap
makes good skin contact and is well grounded when installing
transceiver module.
NOTE:
The ESD-preventive wrist strap is not provided with the wireless
switch. Order it yourself.
To attach the ESD-preventive wrist strap, perform the following steps:
1.
Wear the wrist strap on your wrist.