H3C UniServer R6900 G5 Server 

Processor Installation Quick Start 

 

 

 
 

 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
New H3C Technologies Co., Ltd.  
http://www.h3c.com 
 
Document version: 6W100-20210414

 

 

Содержание UniServer R6900

Страница 1: ...H3C UniServer R6900 G5 Server Processor Installation Quick Start New H3C Technologies Co Ltd http www h3c com Document version 6W100 20210414...

Страница 2: ...espective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be accur...

Страница 3: ...equired syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of optional syntax choices separated by vertical bars from which you select one or none x...

Страница 4: ...switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller...

Страница 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Страница 6: ...i Content Overview 1 Processor kit 1 Preparing for installation 1 Installing the processor 3 Installing DIMMs 9 Starting the server 10...

Страница 7: ...avoid processor and system board damage only H3C authorized personnel and professional server engineers can install a processor To prevent ESD damage to electronic components wear an ESD wrist strap b...

Страница 8: ...move the chassis air baffle As shown in Figure1 2 press the blue latches in the notches at two sides of the air baffle against each other and then lift the air baffle up to remove it from the chassis...

Страница 9: ...N When you remove the protective cover from the heatsink be careful not to touch the thermal grease on the heatsink Figure1 3 Removing the protective cover 2 Install the retaining bracket onto the hea...

Страница 10: ...ways hold the processor by the edges Never touch the gold contacts on the processor bottom a Tilt the processor and align the small triangle on the processor with the alignment triangle on the retaini...

Страница 11: ...the processor socket cover CAUTION Be careful not to touch the pins on the processor socket when you wear ESD gloves to remove the processor socket cover The pins on the processor socket are very fra...

Страница 12: ...ocket cover 5 Install the heatsink onto the server a Align the alignment triangle on the retaining bracket with the cut off corner of the processor socket and the pin holes in the heatsink with the gu...

Страница 13: ...7 Figure1 9 Attaching the heatsink to the processor socket Figure1 10 Holding a heatsink b Press down the heatsink clips at the four corners to lock the heatsink in place...

Страница 14: ...the four captive screws on the heatsink CAUTION The screwdriver torque is in the range of 6 to 12 in lb As a best practice use a torque of 8 in lb to avoid poor contact of the processor or damage to...

Страница 15: ...13 Opening the retaining clips of the DIMM slot 2 Align the notch on the DIMM bottom edge with the key on the DIMM slot 3 Insert the DIMM into the slot and make sure the retaining clips lock the DIMM...

Страница 16: ...ns on the air baffle with the notches on the chassis edges and then place the air baffle into the chassis Figure1 15 Installing the chassis air baffle 2 Install the access panel a Place the access pan...

Страница 17: ...rver front to secure itself into place c Optional Lock the locking lever Use a T15 Torx screwdriver to turn the screw on the lever 90 degree clockwise Figure1 16 Installing the access panel 3 Install...