7-30
Figure 7-34 Removing the dual SD card extended module
5.
Remove the SD cards installed on the extended module, as shown in
.
6.
Install a new dual SD card extended module to the management module and install the
removed SD cards. For more information, see "
7.
Install the management module. For more information, see "
8.
Reconnect the cables to the management module.
9.
Connect the power cord. For more information, see "
10.
Power on the server. For more information, see "
Replacing an NVMe SSD expander module
WARNING!
To avoid bodily injury from hot surfaces, allow the server and its internal modules to cool before
touching them.
The procedure is the same for replacing a 4-port NVMe SSD expander module and an 8-port NVMe
SSD expander module. This section uses a 4-port NVMe SSD expander module as an example.
To replace an NVMe SSD expander module:
1.
Power off the server. For more information, see "
2.
Remove the security bezel, if any. For more information, see "
3.
Remove the compute module. For more information, see "
."
4.
Remove the compute module access panel. For more information, see "
5.
Remove the NVMe SSD expander module: