17
Configuring hot spare drives
CAUTION:
With hot spare drives configured, if a RAID level is degraded due to drive failures, hot spare drives
replace the failed drives automatically. The system starts RAID rebuilding automatically after
accessing the OS.
1.
On the RSTe configuration screen, select
Mark Disks as Spare
, and press
Enter
.
Figure 25 RSTe configuration screen
2.
Select a drive for hot spare, press
SPACE
, and then press
Enter
. On the prompt that opens,
enter
y
and press
Enter
.
Figure 26 Selecting a drive for hot spare
3.
View the configured hot spare information on the RSTe configuration screen.
Содержание UniServer E3200 G3
Страница 35: ...19 Figure 29 Selecting the RAID volume to be deleted...
Страница 116: ...56 Figure 96 Controller Configuration screen...
Страница 220: ...61 Figure 109 Selecting Main Menu 2 Select Controller Management and press Enter...
Страница 243: ...84 Figure 153 Confirming the operation...
Страница 293: ...50 Figure 89 Clearing completion...
Страница 382: ...21 Figure 27 Storage controller information...
Страница 389: ...7 Figure 8 Identifying a storage controller 2...