69
Figure 97 Installing a GPU module
9.
Install the riser card on PCIe riser connector 1, and then fasten the captive screw to the chassis
air baffle, as shown in
.
10.
Connect cables for the GPU module as needed.
11.
Install the access panel. For more information, see "
."
12.
Rack-mount the server. For more information, see "
13.
Connect the power cord. For more information, see "
14.
Power on the server. For more information, see "
Verifying the installation
Log in to HDM to verify that the GPU module is operating correctly. For more information, see HDM
online help.
Installing Ethernet adapters
Guidelines
You can install an mLOM Ethernet adapter only in the mLOM Ethernet adapter connector on the
system board. For more information about the connector location, see "System board components."
A riser card is required when you install a PCIe Ethernet adapter. For more information about PCIe
Ethernet adapter and riser card compatibility, see "Riser cards."
By default, port 1 on the mLOM Ethernet adapter acts as the HDM shared network port. If only a
PCIe Ethernet adapter exists and the PCIe Ethernet adapter supports NCSI, port 1 on the PCIe
Ethernet adapter acts as the HDM shared network port. You can configure another port on the PCIe
Ethernet adapter as the HDM shared network port from the HDM Web interface. For more
information, see HDM online help.
Installing an mLOM Ethernet adapter
Procedure
1.
Power off the server. For more information, see "