47
Figure 60 Installing a drive
4.
(Optional.) Install the removed security bezel. For more information, see "
Verifying the installation
Use the following methods to verify that the drive is installed correctly:
•
Verify the drive properties (including capacity) by using one of the following methods:
{
Log in to HDM. For more information, see HDM online help.
{
Access the UIS manager and click the
Storage
tab. For more information, see the storage
controller user guide for the server.
•
Observe the drive LEDs to verify that the drive is operating correctly. For more information, see
"Drive LEDs."
Installing power supplies
Guidelines
•
The power supplies are hot swappable.
•
Make sure the installed power supplies are the same model. HDM will perform power supply
consistency check and generate an alarm if the power supply models are different.
•
To avoid hardware damage, always use H3C-approved power supplies.
•
The power supplies have an overtemperature protection mechanism. A power supply stops
working when an overtemperature occurs and automatically recovers when the
overtemperature condition is removed.
Procedure
1.
As shown in
, remove the power supply blank from the target power supply slot.