11
Status
Description
Analysis
Off
The power input is
incorrect.
This status occurs when any of the following conditions
exists:
•
The power supply is faulty.
•
A power cord connection failure has occurred.
•
The external power supply is unavailable.
•
The power supply is not switched on.
PSR1400-A/PSR2500-12AHD/PSR2500-12D power supply
LEDs
Table 34 PSR1400-A/PSR2500-12AHD/PSR2500-12D power supply LED description
Status
Description
Analysis
INPUT
Green
The power is input
correctly.
N/A
Red
The power input is
incorrect.
The input voltage is not in the rated voltage range.
Off
No power is input.
This status occurs when any of the following conditions exists:
•
The power supply is faulty.
•
A power cord connection failure has occurred.
•
The external power supply is unavailable.
OUTPUT
Green
The power is output
correctly.
N/A
Red
A power output problem
has occurred.
This status occurs when any of the following conditions exists:
•
The power supply generates an alarm and enters the
protection state due to:
Input under-voltage
Output short-circuit, over-current, or over-voltage
Over temperature
•
The power supply is not switched on.
Off
No power is output.
This status occurs when any of the following conditions exists:
•
The power supply is faulty.
•
A power cord connection failure has occurred.
•
The external power supply is unavailable.
FAN
Green
The fans are operating
correctly.
N/A
Red
The fans are operating
incorrect.
This status occurs when any of the following conditions exists:
•
A fan failure has occurred.
•
The power supply is not switched on.
Off
The fans do not operate.
This status occurs when any one of the following conditions exists:
•
The power supply is faulty.