22
Figure 19 Inserting a SAP module
4.
Fasten the captive screws on the SAP module.
5.
Observe the RUN LED on the SAP to verify that the SAP module is installed correctly.
After the router is powered on, the RUN LED on the SAP flashes green once and then fast
flashes (at 8 Hz) until the application software is loaded. When the RUN LED flashes green at 1
Hz, the SAP is operating correctly.
For the SAP LED descriptions, see "
Installing a HIM/MIM/MIC/MIC-X interface module
CAUTION:
•
MIM interface modules are not hot swappable, but the MIC and MIC-X interface modules are hot
swappable.
•
To hot swap a HIM interface module, you must first execute the
remove slot slotnumber
subslot subslotnumber
command (specifying the HIM interface module to be removed in
the command).
•
To avoid hardware damage, when the RUN LED on a FIP module is fast flashing green, do not
install or remove a HIM/MIM/MIC/MIC-X module on it.
Assembling a MIC-X adapter module and MIC interface
module into a MIC-X interface module
IMPORTANT:
A MIC-X-ET16-compatible FIP module supports only one MIC-X-ET16 assembled by a MIC-X
adapter module and a MIC-ET16L interface module.