17
Figure 13 Inserting the RSE-X1 into the slot
4.
Fasten the captive screws on the RSE-X1.
5.
Observe the RUN LED on the RSE-X1 to verify that the RSE-X1 is installed correctly.
After the router is powered on, the RUN LED on the RSE-X1 flashes green at 8 Hz until the
application software is loaded. When the RUN LED flashes green at 1 Hz, the RSE-X1 is
operating correctly.
NOTE:
When two RSE-X1 MPUs are installed on the router, the ACT LED on the active MPU is steady
green. For the MPU LED descriptions, see "
Installing an MCP MPU
You can install an MCP in slot 1 or slot 2. The installation procedure is similar for MCPs. The
following procedure uses installing an MCP-X1 in slot 1 as an example.
An MCP MPU supports only FIP-10 and FIP-20 modules.
To install an MCP:
1.
Loosen the captive screws on the filler panel in the slot, and then remove the filler panel.
2.
Use even pressure to gently push the MCP into slot 1 along the slide rails until positioning pins
on the backplane are seated in the positioning holes, and then push the ejector levers inward to
lock the MCP in position.