7-2
z
Bits per second = 9600
z
Data bits = 8
z
Parity = none
z
Stop bits = 1
z
Flow control = none
z
Emulation = VT100
Reset them if they are not set to these values.
Troubleshooting Application Upgrading
Fault 1
1) Symptom
Boot the V100-E, upgrade Comware software using TFTP, and the system displays the following:
Net Port Download Menu:
1: Change Net Parameter
2: Download From Net
3: Exit to Main Menu
Enter your choice(1-3): 2
Starting the TFTP download...
Failed to connect the tftp server!!
Please check the network setting!!
2) Solution
The above symptom may be caused by either of the two problems:
z
The TFTP server program does not run.
z
The Ethernet is not connected properly.
Run the TFTP server program on the system, confirm that the IP address is set correctly and the
network cables are connected.
Fault 2
1) Symptom
Boot the V100-E, upgrade Comware software using TFTP, and the system displays the following:
Net Port Download Menu:
1: Change Net Parameter
2: Download From Net
3: Exit to Main Menu
Enter your choice(1-3): 2
Starting the TFTP download...
Failed to find the updated file
Please check the network setting!!
2) Solution
The above symptom is caused by either of the two problems: