5-33
Field
Description
FreeRatio
Free memory ratio.
-/+ Buffers/Cache
-/+ Buffers/Cache:used = Mem:Used – Mem:Buffers – Mem:Cached,
which indicates the physical memory used by applications.
-/+ Buffers/Cache:free = Mem:Free + Mem:B Mem:Cached,
which indicates the physical memory available for applications.
Swap
Swap memory.
Displaying the operational status of power
modules
Use the
display power
command to display the operational status of power modules.
<Sysname> display power
Slot 1 Power 0 Status: Normal
Slot 1 Power 1 Status: Absent
Table5-4 Output description
Field
Description
Power
Number of the power module.
Status
Power module state:
•
Normal
—The power module is operating correctly.
•
Absent
—The power module is not in position.
•
Abnormal
—The power module has failed.
Displaying the temperature information of the
firewall
Use the
display environment
command to display the temperature information of the firewall.
<Sysname> display environment
System Temperature information (degree centigrade):
--------------------------------------------------------------------------------
---------
Slot Sensor Temperature LowerLimit Warning-UpperLimit Alarm-UpperLimit
Shutdown-UpperLimit
1 inflow 1 36 0 60 70
NA
1 inflow 2 34 0 60 70
NA
1 outflow 1 42 0 60 70
NA
1 hotspot 1 62 0 80 92
NA