43
If a user role password is lost, the user can skip the configuration file, and then access the
CLI to configure a new password.
If password recovery capability is disabled, console users must restore the factory-default
configuration before they can configure new passwords.
To enhance system security, disable password recovery capability.
To enable or disable password recovery capability:
Step
Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Enable or disabled
password recovery
capability.
Enable the feature:
password-recovery enable
Disable the feature:
undo password-recovery
enable
By default, password recovery
capability is enabled.
Running Comware images
Enter
1
in the EXTEND-BOOTWARE menu.
Enter your choice(0-9): 1
Loading the main image files...
Loading file cfa0:/main-cmw710-system-e8526.bin.........................
............................................................................
.....................................................Done.
Loading file cfa0:/main-cmw710-boot-e8526.bin...........................
...................................Done.
Image file cfa0:/main-cmw710-boot-e8526.bin is self-decompressing.......
............................................................................
........Done.
System image is starting...
Accessing the Serial submenu
Enter
2
in the EXTEND-BOOTWARE menu.
Enter your choice(0-9): 2
===========================<Enter Serial SubMenu>===========================
|Note:the operating device is sda0 |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Download Files(*.*) |
|<5> Modify Serial Interface Parameter |
|<0> Exit To Main Menu |
============================================================================
Enter your choice(0-5):