44
Table 16 Serial submenu options
Option
Tasks
<1> Download Image Program To
SDRAM And Run
Load and run Comware images in SDRAM.
This option is available only if password recovery capability is
enabled.
<2> Update Main Image File
Download Comware images to the current storage medium as
the main images (the file attribute is set to M).
As a result, the M file attribute of the original main images is
removed.
<3> Update Backup Image File
Download Comware images to the current storage medium as
backup images (the file attribute is set to B).
As a result, the B file attribute of the original backup images is
removed.
<4> Download Files(*.*)
Download files from the server to the device.
<5> Modify Serial Interface Parameter
Change the baud rate of the console port.
The baud rate change is a one-time operation. The baud rate
will restore to the default (9600 bps) at reboot. To set up a
console session with the device after a reboot, you must
change the baud rate setting on the configuration terminal to
9600 bps.
<0> Exit To Main Menu
Return to the EXTENDED-BOOTWARE menu.
NOTE:
To set the current storage medium, see "
Accessing the Ethernet submenu
You can upgrade the Comware software through the management Ethernet port from the Ethernet
submenu and configure file transfer settings.
14.
Enter
3
in the EXTENDED-BOOTWARE menu and press
Enter
to access the Ethernet
submenu.
Enter your choice(0-9):3
==========================<Enter Ethernet SubMenu>==========================
|Note:the operating device is sda0 |
|<1> Download Image Program To SDRAM And Run |
|<2> Update Main Image File |
|<3> Update Backup Image File |
|<4> Download Files(*.*) |
|<5> Modify Ethernet Parameter |
|<0> Exit To Main Menu |
|<Ensure The Parameter Be Modified Before Downloading!> |
============================================================================
Enter your choice(0-5):