7
Table 4
Distance requirements between the front and rear rack posts
Switch model
Installation method
Minimum distance
between the front and
rear rack posts
Maximum distance
between the front and
rear rack posts
S7502E-XS
Using provided
mounting brackets
and chassis rails
520 mm (20.47 in)
789 mm (31.06 in)
S7504E-XS
Using provided
mounting brackets
and chassis rails
518 mm (20.39 in)
888 mm (34.96 in)
Attaching the mounting brackets, chassis rails, and grounding
cable to the chassis
The switch has one mounting position near the network ports and one mounting position near the power
modules for mounting brackets.
The S7504E-XS switch provides three grounding points: primary grounding point (with a grounding sign),
auxiliary grounding point 1, and auxiliary grounding point 2. The S7502E-XS switch provides two
grounding points: primary grounding point (with a grounding sign) and auxiliary grounding point 1.
Figure 7
Mounting and grounding positions on the S7504E-XS switch
(1) Auxiliary grounding point 2
(2) Power module-side mounting position
(3) Network-port-side mounting position
(4) Auxiliary grounding point 1
(5) Primary grounding point