Preparing for installation ················································································ 1

 

Safety recommendations ··································································································································· 2

 

Examining the installation site ···························································································································· 2

 

Temperature/humidity ································································································································ 2

 

Cleanliness ················································································································································· 3

 

EMI ····························································································································································· 3

 

Laser safety ················································································································································ 4

 

Installation tools ················································································································································· 4

 

Installing the switch ························································································ 5

 

Installing the switch in a 19-inch rack················································································································· 6

 

Installation accessories ······························································································································ 6

 

Rack-mounting procedures at a glance ····································································································· 9

 

Attaching the mounting brackets, chassis rails, and grounding cable to the chassis······························· 11

 

Attaching the slide rails to the rack ·········································································································· 18

 

Mounting the switch in the rack ················································································································ 19

 

Grounding the switch by using a grounding strip ····························································································· 21

 

Installing and removing a fan tray ···················································································································· 22

 

Installing a fan tray ··································································································································· 23

 

Removing a fan tray ································································································································· 24

 

Installing and removing a power module·········································································································· 26

 

Installing a power module ························································································································ 26

 

Removing a power module ······················································································································ 27

 

Connecting the power cord ······························································································································ 30

 

Connecting the power cord for an 
LSVM1AC300/LSVM1AC650/PSR250-12A/PSR250-12A1/PSR450-12A/PSR450-12A1 power module30

 

Connecting the power cord for an LSVM1DC300/LSVM1DC650 power module ···································· 31

 

Connecting the power cord for a PSR450-12AHD power module ··························································· 31

 

Connecting the power cord for a PSR450-12D power module ································································ 32

 

Installing and removing an expansion module ································································································· 33

 

Installing an expansion module ················································································································ 33

 

Removing an expansion module ·············································································································· 34

 

Verifying the installation ··································································································································· 35

 

Accessing the switch for the first time ·························································· 36

 

Setting up the configuration environment ········································································································ 36

 

Connecting the console cable ·························································································································· 36

 

Serial console cable ································································································································· 36

 

USB mini console cable ··························································································································· 37

 

Connection procedure ······························································································································ 37

 

Setting terminal parameters ····························································································································· 39

 

Powering on the switch ···································································································································· 39

 

Setting up an IRF fabric ··············································································· 41

 

IRF fabric setup flowchart ································································································································ 41

 

Planning IRF fabric setup ································································································································· 42

 

Planning IRF fabric size and the installation site ······················································································ 42

 

Identifying the master switch and planning IRF member IDs ··································································· 42

 

Planning IRF topology and connections··································································································· 43

 

Identifying physical IRF ports on the member switches ··········································································· 44

 

Planning the cabling scheme ··················································································································· 44

 

Configuring basic IRF settings ························································································································· 46

 

Connecting the physical IRF ports ··················································································································· 46

 

Accessing the IRF fabric to verify the configuration ························································································· 46

 

Maintenance and troubleshooting ································································ 48

 

Power module failure ······································································································································· 48

 

Содержание S6800 Series

Страница 1: ...for an LSVM1DC300 LSVM1DC650 power module 31 Connecting the power cord for a PSR450 12AHD power module 31 Connecting the power cord for a PSR450 12D power module 32 Installing and removing an expansi...

Страница 2: ...B FRUs and compatibility matrixes 68 Power modules 70 Fan trays 71 Expansion modules 74 Appendix C Ports and LEDs 77 Ports 77 Console port 77 Management Ethernet port 77 USB port 78 SFP port 79 QSFP p...

Страница 3: ...6800 54QT H1 LS 6800 54QT H3 S6800 54HF LS 6800 54HF S6800 54HT LS 6800 54HT S6800 2C LS 6800 2C LS 6800 2C H1 S6800 2C FC LS 6800 2C FC S6800 4C LS 6800 4C LS 6800 4C H1 You can view the product cod...

Страница 4: ...your switch in a rack and verify the following items Adequate clearance is reserved at the air inlet and outlet vents for ventilation The rack has a good ventilation system Identify the hot aisle and...

Страница 5: ...ncentration mg m 3 SO2 0 2 H2S 0 006 NH3 0 05 Cl2 0 01 EMI All electromagnetic interference EMI sources from outside or inside of the switch and application system adversely affect the switch in the f...

Страница 6: ...r light Do not stare into beams or view directly with optical instruments when the switch is operating The S6800 switches are Class 1 laser devices Installation tools No installation tools are provide...

Страница 7: ...reby Figure 3 Hardware installation flow Ground the switch Install the switch Start Connect the power cords Verify the installation Switch on the circuit breakers to power on the switch Operating corr...

Страница 8: ...4QT H3 1U high one pair provided See Figure 5 1U high including one pair of chassis rails and one pair of long slide rails provided See Figure 10 1U high including one pair of chassis rails and one pa...

Страница 9: ...0 54QF LS 6800 54QF and LS 6800 54QF H1 switches Figure 5 Mounting brackets for the S6800 54QF LS 6800 54QF H3 and S6800 54QT LS 6800 54QT H3 switches Figure 6 Mounting brackets for the S6800 2C and S...

Страница 10: ...and super short slide rail 1 Chassis rail 2 Super short slide rail Figure 9 1U chassis rail and slide rail 1 Chassis rail 2 Slide rail Figure 10 1U chassis rail and long slide rail 1 Chassis rail 2 L...

Страница 11: ...ance requirements between the front and rear rack posts Switch model Installation method Minimum distance between the front and rear rack posts Maximum distance between the front and rear rack posts S...

Страница 12: ...s 405 mm 15 94 in 834 mm 32 83 in S6800 54QT LS 6800 54QT H3 Using mounting brackets chassis rails and long slide rails 621 mm 24 45 in 854 mm 33 62 in Using mounting brackets chassis rails and slide...

Страница 13: ...00 2C FC switches each provide two grounding points primary grounding point with a grounding sign and auxiliary grounding point 1 The mounting brackets and chassis rails installation procedures are th...

Страница 14: ...osition 2 Primary grounding point 3 Auxiliary grounding point 1 4 Port side mounting position Figure 16 Mounting and grounding positions on the S6800 54QT LS 6800 54QT H3 switch 1 Power module side mo...

Страница 15: ...ews provided to attach the mounting brackets to the chassis To install the mounting brackets at the power module side see Figure 18 Figure 19 and Figure 20 To install the mounting brackets at the port...

Страница 16: ...r the mounting brackets Figure 19 Attaching the mounting brackets and chassis rails to an S6800 2C S6800 2C FC switch power module side mounting position for the mounting brackets Figure 20 Attaching...

Страница 17: ...s Figure 22 Attaching the mounting brackets and chassis rails to an S6800 54QF LS 6800 54QF H3 switch port side mounting position for the mounting brackets Figure 23 Attaching the mounting brackets an...

Страница 18: ...nting position for the mounting brackets Figure 25 Attaching the mounting brackets and chassis rails to an S6800 54QT LS 6800 54QT H3 switch port side mounting position for the mounting brackets Figur...

Страница 19: ...crew that come with the switch are suitable only for these two grounding points To use auxiliary grounding point 2 prepare a grounding cable yourself This section uses the primary grounding point on t...

Страница 20: ...ttachment position for the slide rails 2 Install cage nuts user supplied in the mounting holes in the rack posts 3 Align the screw holes in one slide rail with the cage nuts in the rack post on one si...

Страница 21: ...rack posts b Pushes the switch slowly to slide the chassis rails along the slide rails until the mounting brackets are flush with the rack posts 6 The other person uses screws user supplied to attach...

Страница 22: ...31 Mounting the S6800 2C switch in the rack port side mounting position for the mounting brackets Figure 32 Mounting the S6800 4C switch in the rack power module side mounting position for the mountin...

Страница 23: ...ding cable to a fire main or lightning rod To guarantee the grounding effect and avoid switch damage use the grounding cable provided with the switch to connect the switch to a grounding strip in the...

Страница 24: ...1 fan tray redundancy The switch can operate correctly with four fan trays In the remaining fan tray slot you can install a fan tray for 4 1 redundancy or a filler panel On the other switch models yo...

Страница 25: ...until the fan tray seats in the slot and has a firm contact with the backplane see callout 1 in Figure 35 4 Fasten the captive screw on the fan tray with a Phillips screwdriver until the fan tray is...

Страница 26: ...t until the fan tray is fully seated in the slot and has a firm contact with the backplane Figure 37 Installing an LSPM1FANSA fan tray Removing a fan tray WARNING Ensure electricity safety and never t...

Страница 27: ...tic bag Removing an LSWM1BFANSC or LSWM1BFANSCB fan tray 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Grasp the fan tray handle with one hand to pull t...

Страница 28: ...1 Removal procedure Installing a power module CAUTION Follow the forward inertia of the power module when inserting it into the chassis and make sure the power module has firm contact with the connect...

Страница 29: ...S6800 54HT S6800 2C or S6800 2C FC switch has two power modules in 1 1 redundancy mode removing one power module does not affect the operation of the switch When the switch has only one power module i...

Страница 30: ...R450 12D power module 1 Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded 2 Remove the power cord from the power module For an LSVM1DC300 or LSVM1DC650 power mo...

Страница 31: ...he screws on the power cord connector 2 Pull the power cord connector out Removing a PSR450 12AHD power module The PSR450 12AHD power module removal procedure is the same for the S6800 54QF LS 6800 54...

Страница 32: ...emoved power module in an antistatic bag Connecting the power cord WARNING Provide a circuit breaker for each power input When you connect a power cord make sure the circuit breaker is switched off Co...

Страница 33: ...g into the receptacle re orient the plug rather than use excessive force to push it in 2 Use a cable tie to secure the power cord to the handle of the power module as shown in Figure 49 3 Connect the...

Страница 34: ...50 12AHD power module 3 Connecting the power cord for a PSR450 12D power module 1 Correctly orient the DC power cord plug and insert the plug into the power receptacle on the power module If you orien...

Страница 35: ...the same This section uses the LSWM18QC interface module as an example Installing an expansion module 1 Wear an ESD wrist strap and make sure the wrist strap makes good skin contact and is reliably gr...

Страница 36: ...module remove the cable from it to avoid cable damage If you are not to install a new expansion module after removing the original one install the filler panel in the slot to prevent dust and ensure g...

Страница 37: ...on around the switch and the rack is stable The grounding cable is securely connected The correct power source is used The power cords are correctly connected All the interface cables are cabled indoo...

Страница 38: ...console cable Do not use the two ways together on the same S6800 switch The example uses a console cable to connect a console terminal PC to the serial console port on the switch Figure 59 Connecting...

Страница 39: ...ports on PCs do not support hot swapping If the switch has been powered on connect the serial console cable to the PC before connecting to the switch and when you disconnect the cable first disconnec...

Страница 40: ...38 Figure 61 Device Driver Installation Wizard 6 Click Continue Anyway if the following dialog box appears Figure 62 Software Installation 7 Click Finish...

Страница 41: ...minal emulator programs see the user guides for these programs The following are the required terminal settings Bits per second 9600 Data bits 8 Stop bits 1 Parity None Flow control None Powering on t...

Страница 42: ...options differ with software versions For more information about Boot ROM menu options see the software matching release notes for the device After the startup completes you can access the CLI to conf...

Страница 43: ...and LS 6800 54QF H3 S6800 54QT LS 6800 54QT H1 and LS 6800 54QT H3 S6800 2C LS 6800 2C H1 and S6800 4C LS 6800 4C H1 S6800 32Q LS 6800 32Q S6800 2C LS 6800 2C S6800 4C LS 6800 4C S6800 54QF LS 6800 54...

Страница 44: ...d identify the number of required IRF member switches depending on the user density and upstream bandwidth requirements The switching capacity of an IRF fabric equals the total switching capacities of...

Страница 45: ...hout interrupting network services You connect the IRF member switches through IRF ports the logical interfaces for the connections between IRF member switches Each IRF member switch has two IRF ports...

Страница 46: ...cording to your topology and connection scheme All the 10GBase T Ethernet ports SFP ports QSFP ports and QSFP28 ports on the S6800 switch can be used for IRF connections Planning the cabling scheme Yo...

Страница 47: ...itches in one rack Figure 68 IRF fabric topology Connecting the IRF member switches in a ToR solution You can install IRF member switches in different racks side by side to deploy a top of rack ToR so...

Страница 48: ...transceiver modules and optical fibers For more information see the installation guide for the transceiver modules Use cables or transceiver modules and optical fibers to connect the IRF member switch...

Страница 49: ...etection MAD mechanism to detect the presence of multiple identical IRF fabrics and handle collisions For more information about MAD detection see H3C S6800 Switch Series IRF Configuration Guide or H3...

Страница 50: ...e system outputs alarm messages When an LSWM1BFANSC or LSWM1BFANSCB fan tray has problems the Alarm LED on the fan tray is steady yellow and the system outputs alarm messages When an LSPM1FANSA or LSP...

Страница 51: ...cable 3 Verify that the following settings are configured for the terminal Baud rate 9600 Data bits 8 Stop bits 1 Parity None Flow control None 4 If the issue persists contact H3C Support Garbled dis...

Страница 52: ...e S6800 32Q switch comes with the two power module slots empty and a filler panel as an accessory You can install one or two power modules for the switch as needed In Figure 71 two LSVM1AC650 power mo...

Страница 53: ...ure 74 Front panel LS 6800 54QF H3 1 SFP port LED 2 SFP port 3 QSFP port LED 4 QSFP port Figure 75 Rear panel LS 6800 54QF LS 6800 54QF H1 1 Grounding screw auxiliary grounding point 2 2 Management Et...

Страница 54: ...slots In Figure 76 two PSR250 12A power modules are installed in the power module slots For more information about installing and removing power modules see Installing and removing a power module The...

Страница 55: ...10GBASE T autosensing Ethernet port 2 1 10GBASE T autosensing Ethernet port LED 3 QSFP port 4 QSFP port LED Figure 81 Rear panel LS 6800 54QT LS 6800 54QT H1 1 Grounding screw auxiliary grounding poin...

Страница 56: ...wer module slots In Figure 82 two PSR450 12A1 power modules are installed in the power module slots For more information about installing and removing power modules see Installing and removing a power...

Страница 57: ...ler panel as an accessory You can install one or two power modules for the switch as needed In Figure 86 two LSVM1AC300 power modules are installed in the power module slots For more information about...

Страница 58: ...er module slots empty and a filler panel as an accessory You can install one or two power modules for the switch as needed In Figure 89 two LSVM1AC650 power modules are installed in the power module s...

Страница 59: ...nstalling and removing expansion modules see Installing and removing an expansion The S6800 2C switch comes with the two power module slots empty and a filler panel as an accessory You can install one...

Страница 60: ...removing expansion modules see Installing and removing an expansion module The S6800 2C FC switch comes with the two power module slots empty and a filler panel as an accessory You can install one or...

Страница 61: ...comes with a filler panel in all expansion slots except slot 1 You can install one to four expansion modules for the switch as needed In Figure 97 the LSWM18QC interface modules are installed in the e...

Страница 62: ...0 54QF S6800 54QF LS 6800 54QF H1 S6800 54QT LS 6800 54QT S6800 54QT LS 6800 54QT H1 Dimensions H W D 43 6 440 660 mm 1 72 17 32 25 98 in 43 6 440 460 mm 1 72 17 32 18 11 in 43 6 440 660 mm 1 72 17 32...

Страница 63: ...Single AC input 155 W Dual AC inputs 170 W Single DC input 160 W Dual DC inputs 180 W LS 6800 54QT H1 Single AC input 135 W Dual AC inputs 150 W Single DC input 132 W Dual DC inputs 142 W Maximum pow...

Страница 64: ...6 440 460 mm 1 72 17 32 18 11 in 43 6 440 660 mm 1 72 17 32 25 98 in Weight 10 kg 22 05 lb 13 kg 28 66 lb Console ports 1 mini USB console port 1 serial console port 1 mini USB console port 1 serial...

Страница 65: ...LSVM1DC650 30 A 250 VDC Operating temperature 0 C to 45 C 32 F to 113 F Operating humidity 10 RH to 90 RH noncondensing Fire resistance compliance UL60950 1 EN60950 1 IEC60950 1 GB4943 Table 10 Techni...

Страница 66: ...age 36 to 72 VDC PSR450 12A PSR450 12A1 AC input Rated voltage 100 to 240 VAC 50 or 60 Hz Max voltage 90 to 290 VAC 47 to 63 Hz High voltage DC input Rated voltage 240 VDC Max voltage 180 to 320 VDC P...

Страница 67: ...C PSR450 12A PSR450 12A1 10 A 250 VAC 10 A 310 VDC PSR450 12AHD 10 A 420 V PSR450 12D 20 A 125 V PSR450 12A PSR450 12A1 10 A 250 VAC 10 A 310 VDC PSR450 12AHD 10 A 420 V PSR450 12D 20 A 125 VDC Operat...

Страница 68: ...AC inputs 156 W Quadruple AC inputs 172 W Dual DC inputs 145 W Triple DC inputs 160 W Quadruple DC inputs 171 W LS 6800 4C H1 Dual AC inputs 135 W Triple AC inputs 150 W Quadruple AC inputs 165 W Dual...

Страница 69: ...50 1 EN60950 1 IEC60950 1 GB4943 Melting current of power module fuse LSVM1AC650 10 A 250 VAC LSVM1DC650 30 A 250 VDC Operating temperature 0 C to 45 C 32 F to 113 F Operating humidity 10 RH to 90 RH...

Страница 70: ...expansion modules available for the switch Table 12 Compatibility matrix between the FRUs and S6800 switches 1 FRUs S6800 32Q S6800 54HF S6800 54HT S6800 54QF LS 6800 54QF S6800 54QF LS 6800 54QF H1 S...

Страница 71: ...No Yes in Release 2509P02 and later LSWM18CQMSEC Yes in Release 2612 and later No Yes in Release 2612 and later LSWM124XGT2Q Yes in Release 2509P02 and later No Yes in Release 2509P02 and later LSWM1...

Страница 72: ...dundancy you can replace a power module without powering off the switch Make sure the power module to be replaced is powered off before you replace it IMPORTANT As a best practice use power modules of...

Страница 73: ...input voltage 90 VAC to 290 VAC 47 Hz to 63 Hz Max output power 450 W DC input Rated input voltage 240 VDC Max input voltage 180 VDC to 320 VDC Max output power 450 W For more information about the p...

Страница 74: ...9 in fan Fan speed 20000 R P M Max airflow 120 CFM Airflow direction From the power module side to the port side Input voltage 12 V Maximum power consumption 57 W Documentation reference H3C LSWM1BFAN...

Страница 75: ...Fan speed 20000 R P M Max airflow 20 CFM Airflow direction From the power module side to the port side Input voltage 12 V Maximum power consumption 9 8 W Documentation reference H3C LSPM1FANSA LSPM1FA...

Страница 76: ...ports LSWM124XG2 QL 24 Port SFP Plus and 2 Port QSFP Plus Interface Module LSWM124XG2 QFC 24 Ports SFP Plus and 2 Ports QSFP Plus Interface Module with FC LSWM12H2Q 2 Port QSFP28 and 2 Port QSFP Plus...

Страница 77: ...terface modules in the slot If you change the interface module type in a slot you need to reboot the switch for the interface module to operate correctly You must install the same type of interface mo...

Страница 78: ...delivery engine ADE module It provides powerful load balancing and service optimization functions You can deploy it on a switch at the aggregate or core layer of a data center to accelerate the respo...

Страница 79: ...e port Mini USB console port Connector type RJ 45 USB mini Type B Compliant standard EIA TIA 232 USB 2 0 Transmission baud rate 9600 bps default to 115200 bps Services Provides connection to an ASCII...

Страница 80: ...e 24 FE SFP transceiver modules FE SFP transceiver module Central wavelength nm Connector Fiber type and diameter m Max transmission distance SFP FE SX MM1310 A 1310 LC Multi mode 50 125 2 km 1 24 mil...

Страница 81: ...SM1310 transceiver modules Table 25 Gigabit SFP transceiver modules available for the SFP ports Gigabit SFP transceiver module Central wavelength nm Connector Cable Fiber type and diameter m Modal ba...

Страница 82: ...ulti mode 62 5 125 200 150 m 492 13 ft Multi mode 50 125 500 380 m 1246 72 ft 2000 500 m 1640 42 ft SFP FC 8G L W SM1310 1310 LC Single mode 9 125 N A 10 km 6 21 miles SFP FC 16G SW MM850 840 to 860 L...

Страница 83: ...Pull latch Figure 101 SFP fiber cable NOTE As a best practice use H3C SFP transceiver modules SFP transceiver modules or SFP cables for the SFP ports on the switch The H3C SFP transceiver modules SFP...

Страница 84: ...ti mode 50 125 2000 100 m 328 08 ft 4700 150 m 492 12 ft QSFP 40G CSR4 MM850 850 MPO Multi mode 50 125 2000 300 m 984 25 ft 4700 400 m 1312 33 ft QSFP 40G BIDI SR MM850 850 LC Multi mode 50 125 2000 1...

Страница 85: ...sion distance Data rate QSFP 40G D AOC 7M 7 m 22 97 ft 40 Gbps QSFP 40G D AOC 10M 10 m 32 81 ft QSFP 40G D AOC 20M 20 m 65 62 ft Figure 102 QSFP cable 1 Connector 2 Pull latch Figure 103 QSFP to SFP c...

Страница 86: ...fiber type NOTE As a best practice use H3C QSFP transceiver modules QSFP cables or QSFP to 4 SFP cables for the QSFP ports The H3C QSFP transceiver modules QSFP cables and QSFP to 4 SFP cables are su...

Страница 87: ...Four lanes 1295 1300 1304 1309 LC Single mode 9 125 N A 10 km 6 21 miles QSFP 100G LR4 L WDM1300 Four lanes 1264 5 to 1277 5 1284 5 to 1297 5 1304 5 to 1317 5 1324 5 to 1337 5 LC Single mode 9 125 N A...

Страница 88: ...ll duplex MDI MDI X autosensing Transmission medium and max transmission distance 55 m 180 45 ft over category 6 unshielded twisted pair cable 100 m 328 08 ft over category 6 shielded twisted pair cab...

Страница 89: ...green The port is sending or receiving data at 10 Gbps Steady yellow A transceiver module or cable has been correctly installed The port has a link and is operating at 1 Gbps Flashing yellow The port...

Страница 90: ...LED and one ACT LED for the management Ethernet port See Table 41 Table 41 Copper management Ethernet port LED description 1 LED mark Status Description LINK Off No link is present Steady green The p...

Страница 91: ...e the interface status For an LSWM116FC interface module installed on an S6800 2C or S6800 4C switch all its interfaces are 32G FC interfaces by default See Table 45 for the FC interface LED descripti...

Страница 92: ...ED The LSWM1BFANSC LSWM1BFANSCB LSPM1FANSA and LSPM1FANSB fan trays each provide an Alarm LED Table 46 Fan tray alarm LED description Status Description On The fan tray is faulty Off The fan tray is o...

Страница 93: ...NSC From the power module side to the port side LSWM1HFANSCB From the port side to the power module side S6800 4C LSWM1BFANSC From the power module side to the port side LSWM1BFANSCB From the port sid...

Страница 94: ...92 Figure 107 Airflow from the port side to the power module side through the S6800 32Q chassis with LSWM1HFANSCB fan trays...

Страница 95: ...an tray failure 48 G Grounding the switch by using a grounding strip 21 I Installation tools 4 Installing and removing a fan tray 22 Installing and removing a power module 26 Installing and removing a...

Отзывы: