Installing an S5820X-26S switch in a 19-inch
rack
Table 1
Installing an S5820X-26S switch in a 19-inch rack
Installation procedure
Remarks Installation diagram
1.
Attach the mounting
brackets to the
switch.
Required
•
For mounting near the power
modules, see
.
•
For mounting near the ports,
see
2.
Attach chassis rails
to the switch.
Required
•
For mounting near the ports,
see
.
•
For mounting near the power
modules, see
3.
Install cage nuts in
the rack posts.
4.
Attach slide rails to
the rack posts.
5.
Connect the
grounding cable to
the primary
grounding point.
6.
Install the switch in
the rack.
Required
See
. This figure uses the
mounting position near the power
modules as an example.
NOTE:
•
The depth of the rack must be a minimum of 1000 mm (39.37 in).
•
The S5820X-26S switch has three grounding points, as shown in
. The primary grounding point and auxiliary grounding point 1 are
on the right side panel. If you use one of these grounding points, you
must connect the grounding cable to the grounding point before you
mount the switch in the rack.