169
Field Description
LowerLimit
Temperature lower limit.
WarningLimit
Warning temperature threshold.
AlarmLimit
Alarming temperature threshold.
ShutdownLimit
Shutdown temperature threshold. When the sensor temperature reaches this limit, the
system shuts down automatically.
Related commands
temperature-limit
display fan
Use
display fan
to display the operating states of fan trays.
Syntax
display fan
[
slot
slot-number
[
fan-id
] ] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
Views
Any view
Default command level
1: Monitor level
Parameters
slot
slot-number
: Displays the operating states of fan trays on an IRF member device. The
slot-number
argument represents the IRF member ID of the device. If no IRF member device is specified, this command
displays the operating states of fan trays on all IRF member devices.
fan-id
: Displays the operating state of the specified fan tray, where the
fan-id
argument represents the fan
tray ID.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Examples
# Display the operating states of all fan trays on an S5800-54S or S5820X-26S.
<Sysname> display fan
Slot 1
FAN 1
State : Normal
Wind Direction :Power-to-Port
Prefer Wind Direction :Power-to-Port
FAN 2
State : Normal