168
…
display environment
Use
display environment
to display temperature information, including the current temperature and
temperature thresholds.
Syntax
display environment
[
slot
slot-number
] [
|
{
begin
|
exclude
|
include
}
regular-expression
]
Views
Any view
Default command level
1: Monitor level
Parameters
slot
slot-numbe
r: Displays temperature information for an IRF member device. The
slot-number
argument
represents the IRF member ID of the device.
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Usage guidelines
If no IRF member device is specified and the
vent
keyword is not specified, this command displays
temperature information for all sensors in the IRF fabric.
Examples
# Display temperature information.
<Sysname> display environment
Slot 2
System temperature information (degree centigrade):
-----------------------------------------------------------------------------
Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
hotspot 1 44 5 70 80 NA
hotspot 2 37 -10 125 135 NA
Table 27
Command output
Field Description
Sensor
Temperature sensor:
hotspot
—A hotspot sensor.
Slot
A number in this field indicates an IRF member device. The "vent" in this field indicates
a sensor on the frame or fan tray.
Temperature Current
temperature.