11
Configuring link monitoring
NOTE:
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured in
this section take effect on all Ethernet ports automatically.
Configuring errored symbol event detection
An errored symbol event occurs when the number of detected symbol errors over a specific detection
interval exceeds the configured threshold.
Follow these steps to configure errored symbol event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored
symbol event detection
interval
oam errored-symbol period
period-value
Optional
1 second by default
Configure the errored
symbol event triggering
threshold
oam errored-symbol threshold
threshold-value
Optional
1 by default
Configuring errored frame event detection
An errored frame event occurs when the number of detected error frames over a specific interval exceeds
the configured threshold.
Follow these steps to configure errored frame event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored frame
event detection interval
oam errored-frame period
period-value
Optional
1 second by default
Configure the errored frame
event triggering threshold
oam errored-frame threshold
threshold-value
Optional
1 by default
Configuring errored frame period event detection
An errored frame period event occurs if the number of frame errors in specific number of received frames
exceeds the configured threshold.
Follow these steps to configure errored frame period event detection:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Configure the errored frame
period event detection
period
oam errored-frame-period period
period-value
Optional
1000 milliseconds by default