4-21
[DeviceA-GigabitEthernet1/0/50]
%Jan 18 18:22:46:065 2010 DeviceA IFNET/3/LINK_UPDOWN: GigabitEthernet1/0/50 link status
is UP.
The output above indicates that the link status of both GigabitEthernet 1/0/50 and GigabitEthernet
1/0/51 is now up.
Troubleshooting DLDP
Symptom
Two DLDP-enabled devices, Device A and Device B, are connected through two fiber pairs, in which
two fibers are cross-connected. The unidirectional links cannot be detected; all the four ports involved
are in Advertisement state.
Analysis
The problem can be caused by the following.
z
The intervals to send Advertisement packets on Device A and Device B are not the same.
z
DLDP authentication modes/passwords on Device A and Device B are not the same.
Solution
Make sure the interval to send Advertisement packets, the authentication mode, and the password
configured on Device A and Device B are the same.