53
Appendix B FRUs and compatibility matrixes
This appendix describes the field replaceable units (FRUs) available for the S5120-HI switches and their
compatibility.
All the FRUs in this appendix are hot swappable.
FRUs and compatibility matrixes
FRUs S5120-28SC-HI
S5120-52SC-HI
S5120-34C-HI S5120-58C-HI
Hot swappable power modules
PSR150-A Supported Supported Supported
Supported
PSR150-A1 Supported Supported
Supported
Supported
PSR150-D Supported Supported Supported
Supported
PSR150-D1 Supported Supported
Supported
Supported
Hot swappable fan trays
LSPM1FAN Supported Supported
N/A
N/A
LSPM1FANB Supported
Supported
N/A
N/A
Interface cards
LSPM1XP1P Supported
Supported
Supported
Supported
LSPM1XP2P Supported
Supported
Supported
Supported
LSPM1CX2P Supported
Supported
Supported
Supported
LSPM2SP2P Supported
Supported
Supported
Supported
LSPM2GP2P Supported
Supported
Supported
Supported
LSPM1XGT2P Supported
Supported
Supported
Supported
LSP5GP8P0 N/A
N/A
Only supported by
SLOT1
Supported
LSP5GT8P N/A
N/A
Only supported by
SLOT1
Supported
NOTE:
•
PSR150-A1 and PSR150-D1 support asset management, and PSR150-A and PSR150-D do not. If the
switch is installed with a power module that supports asset management, you can use the
display device
manuinfo
command to view the device name, serial number, MAC address, and vendor of switch.
•
You can install one power module, or for redundancy, two power modules for your switch.
•
The power modules of PSR150-A/PSR150-A1 and PSR150-D/PSR150-D1 support intermixing.
Hot swappable power modules