Operation Manual – MSTP
H3C S3100-52P Ethernet Switch
Chapter 1 MSTP Configuration
1-59
1.14 VLAN-VPN tunnel Configuration Example
I. Network requirements
z
Switch C and Switch D are the access devices for the service provider network.
z
Switch A and Switch B are the access devices for the customer networks.
z
Switch C and Switch D are connected to each other through the configured trunk
ports of the switches. The VLAN-VPN tunnel function is enabled in system view,
thus implementing transparent transmission between the customer networks and
the service provider network.
II. Network diagram
Figure 1-11
Network diagram for VLAN-VPN tunnel configuration
III. Configuration procedure
1) Configure Switch A
# Enable MSTP.
<Sysname> system-view
[Sysname] stp enable
# Add Ethernet 1/0/1 to VLAN 10.
[Sysname] vlan 10
[Sysname-Vlan10] port Ethernet 1/0/1
2) Configure Switch B
# Enable MSTP.
<Sysname> system-view
[Sysname] stp enable
# Add Ethernet 1/0/1 to VLAN 10.
[Sysname] vlan 10
[Sysname-Vlan10] port Ethernet 1/0/1
3) Configure Switch C
# Enable MSTP.