Powering on the switch
Before powering on the switch, confirm the following:
•
You know where the emergency power-off switch for the equipment room is located.
•
The switch has been securely mounted.
•
All the cards have been correctly installed.
•
The unused slots have been installed with filler panels.
•
All the network cables, fibers, power cables, and grounding cables have been correctly connected.
•
The input power voltage meets the requirement of the switch.
•
The console cable is correctly connected, the terminal or PC used for configuration has started, and
the configuration parameters have been set.
To power on the switch:
Turn on the power source of the switch to power on the switch.
The following is a sample output you can see on the terminal:
System is starting...
Booting Normal Extend BootWare.
The Extend BootWare is self-decompressing...................................
.....Done!
****************************************************************************