Unplug the power cord before cleaning the 
RPS unit. 

z

 

Keep the equipment room clean. The limits on 
the concentrations of dust and harmful gases 
in the equipment room are shown in the 
following tables: 

Table 4  

Limit on dust concentration 

Mechanical 

active material 

Limit (particles/m³) 

Dust particles 

 3 × 10

4

 (No visible dust on tabletop 

over three days) 

Note: Dust particle size 

 5µm 

 

Table 5  

Limits on harmful gas concentration 

Gas 

Limit (mg/m

3

SO

2

 0.2 

H

2

S 0.006 

NH

3

 0.05 

Cl

2

 0.01 

 

3.2  Installing the RPS Unit 

The RPS500-A3 can be installed either in a 

19-inch standard rack or directly on a tabletop.  

Содержание RPS500-A3

Страница 1: ...RPS500 A3 User Manual Hangzhou H3C Technologies Co Ltd http www h3c com Manual Version 20080428 C 1 04...

Страница 2: ...NetPilot Neocean NeoVTL SecPro SecPoint SecEngine SecPath Comware Secware Storware NQA VVG V 2 G V n G PSPT XGbus N Bus TiGem InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd A...

Страница 3: ...the latest information please access http www h3c com Technical Support customer_service h3c com http www h3c com Environmental Protection This product has been designed to comply with the requirement...

Страница 4: ...2 3 Front Panel 4 2 4 Rear Panel 4 2 5 LEDs 4 2 6 Technical Specifications 5 3 Installation 6 3 1 Precautions 6 3 2 Installing the RPS Unit 8 3 2 1 Installing the RPS Unit to a 19 inch Rack 9 3 2 2 In...

Страница 5: ...oot pads 4 2 Product Overview 2 1 Introduction The RPS500 A3 is an external DC power supply unit that uses AC input and provides DC output for multiple switch and router models as a redundant backup p...

Страница 6: ...eiving this LOW signal the RPS unit switches to the DC output state within 2 ms If using the same AC power source with the powered device the RPS500 A3 can timely provide DC supply to the powered devi...

Страница 7: ...PS unit becomes an independent power supply system to feed that powered device 2 2 Features The RPS500 A3 can provide selective DC outputs Depending on the connected DC output cable s the RPS unit can...

Страница 8: ...e 1 Front panel of the RPS500 A3 2 4 Rear Panel 1 AC input 2 DC output Figure 2 Rear panel of the RPS500 A3 2 5 LEDs Table 2 LED description LED Mark on panel Status Meaning On The RPS operates normal...

Страница 9: ...t 3 5 kg 7 72 lb Input 100 to 240 VAC 50 60 Hz Available Outputs z 50 V 7 5 A z 12 V 10 5 A 12 V output only 125 W 50 V output only 375 W Maximu m power consum ption 12 V and 50 V outputs simultaneous...

Страница 10: ...PS unit on an unstable case or tabletop and ensure that the cabinet and the workbench are firm enough to support the RPS unit and its accessories z Make sure that the ventilation and heat dissipation...

Страница 11: ...age requirement of the RPS unit z Interface cables must be routed indoors Otherwise over voltage and over current may damage the device As for power cables from the outside of the building you may add...

Страница 12: ...ables Table 4 Limit on dust concentration Mechanical active material Limit particles m Dust particles 3 10 4 No visible dust on tabletop over three days Note Dust particle size 5 m Table 5 Limits on h...

Страница 13: ...rack be sure to use a tray or bracket to support the weight of the unit Step 1 Put on an ESD preventive wrist strap and check the grounding and stableness of the rack Step 2 Fix the supporting tray su...

Страница 14: ...wn in Figure 4 Figure 4 Install the RPS unit to a 19 inch rack 2 3 2 2 Installing the RPS Unit on a Tabletop If a 19 inch standard rack is not available you can place the RPS unit directly on a clean...

Страница 15: ...the table 3 3 Connecting the RPS Unit to the Powered Device The RPS500 A3 can be used as a redundant backup power supply unit for multiple switch and router models The following describes how to conn...

Страница 16: ...supply input of the switch Step 3 Plug one end of the RPS DC output cable into the redundant power supply socket on the rear panel of the switch and the other end into the DC output socket of the RPS...

Отзывы: