garp timer hold
Use
garp timer hold
to set the GARP Hold timer for an Ethernet port, Layer-2 aggregate interface,
or all ports in a port group.
Use
undo garp timer hold
to restore the default of the GARP Hold timer. This might fail if the default
is beyond the valid value range for the Hold timer.
Syntax
garp timer hold
timer-value
undo garp timer hold
Default
The Hold timer is 10 centiseconds.
Views
Ethernet interface view, Layer-2 aggregate interface view, port group view
Default command level
2: System level
Parameters
timer-value
: Specifies the Hold timer (in centiseconds), which must be a multiple of 5 and range from
10 (inclusive) to half the Join timer (inclusive).
Usage guidelines
The following matrix shows the command and hardware compatibility:
Hardware Command
compatibility
MSR800 No
MSR 900
No
MSR900-E No
MSR 930
No
MSR 20-1X
No
MSR 20
No
MSR 30
Yes
MSR 50
Yes
MSR 2600
Yes
MSR3600-51F Yes
Examples
# Set the GARP Hold timer to 15 centiseconds, assuming that the Join timer is 30 centiseconds.
<Sysname> system-view
[Sysname] interface ethernet 1/1
[Sysname-Ethernet1/1] garp timer hold 15
Related commands
•
display garp timer
•
garp timer join