background image

Preparing for installation 

H3C Mini Unmanaged Ethernet Switches include the following 
models: 

 

H3C Mini S8G-U (S8G-U). 

 

H3C Mini S9-PWR (S9-PWR). 

 

H3C Mini S16G-U (S16G-U). 

 

H3C Mini S24-U (S24-U). 

 

H3C Mini S24G-U (S24G-U). 

Safety recommendations 

To avoid any equipment damage or bodily injury, read the following 
safety recommendations before installation. The recommendations 
do not cover every possible hazardous condition. 

 

Do not place the switch near water or in a damp environment. 
Prevent water or moisture from entering the chassis. 

 

Place the switch in a clean environment. Dust buildup on the 
chassis might result in electrostatic adsorption, which reduces 
lifespan of the device and can cause communication failure. 

 

Keep the air inlet and outlet vents of the switch free of 
obstruction, and do not stack switches. 

 

Make sure the operating voltage is in the required range. 

 

Before using the switch, make sure the grounding cable of the 
switch is correctly connected. 

 

Before cleaning the switch, remove the power cord from the 
switch. Do not clean the switch with a wet cloth or liquid. 

 

Do not open the chassis while the switch is operating. 

Содержание Mini S16G-U

Страница 1: ...ironment Prevent water or moisture from entering the chassis Place the switch in a clean environment Dust buildup on the chassis might result in electrostatic adsorption which reduces lifespan of the...

Страница 2: ...unting Workbench mounting Wall mounting S8G U Not supported Supported Supported S9 PWR Not supported Supported Supported S16G U Supported Supported Not supported S24 U Supported Supported Not supporte...

Страница 3: ...the switch on a rack shelf in the rack Push the switch in until the oval holes in the brackets align with the mounting holes in the front rack posts 4 Use screws to secure the mounting brackets to th...

Страница 4: ...p and clean the four recessed areas in the chassis bottom with a soft and dry cloth 3 Attach the rubber feet to the recessed areas 4 Place the switch upside up on the workbench Mounting on a wall You...

Страница 5: ...or If you use screws and screw anchors of the recommended size the hole diameter is 5 mm 0 20 in 2 Drill two holes spacing 90 mm 3 54 in on the wall Make sure the two holes are on a horizontal line 3...

Страница 6: ...n a wall Connecting cables Connecting the grounding cable CAUTION Correctly connecting the grounding cable is crucial to lightning protection and EMI protection The switch is not provided with a groun...

Страница 7: ...at the other end of the cable 3 Remove the hex nut from a grounding post on the grounding strip Attach the loop to the grounding post and fasten the hex nut Figure 5 Connecting the grounding cable Co...

Страница 8: ...nnect the power adapter 1 Connect the power cord to the power adapter This step is not required for an S8G U switch 2 Connect the DC connector of the power adapter to the DC power receptacle on the sw...

Страница 9: ...9 Appendix A Chassis views and technical specifications Chassis views Front panel Figure 7 S8G U front panel Figure 8 S9 PWR front panel Figure 9 S16G U front panel...

Страница 10: ...front panel 1 Power LED Power 2 10 100 1000Base T copper port status LED 3 Uplink port status LED 4 10 100Base TX copper port status LED 5 PoE status LED 6 PoE MAX LED 7 10 100 1000Base T copper port...

Страница 11: ...Enable flow control and downshift Disable flow control and enable downshift Enable flow control downshift and uplink port aggregation Ports 15 and 16 on the S16G U and ports 23 and 24 on the S24G U ar...

Страница 12: ...ower receptacle Technical specifications Table 2 Technical specifications 1 Item S8G U S9 PWR S16G U Dimensions H W D 27 158 105 mm 1 06 6 22 4 13 in 27 235 105 mm 1 06 9 25 4 13 in 44 330 173 mm 1 73...

Страница 13: ...7 8 W Power consumption full configuration 4 W 70 W 11 W Cooling system Natural cooling Input voltage DC 12 V 0 5 A DC 54 V 1 48 A AC 100 VAC to 240 VAC 50 Hz or 60 Hz Port specifications RJ 45 connec...

Страница 14: ...n Weight 1 5 kg 3 31 lb 1 6 kg 3 53 lb Port 24 10 100Base TX copper port 24 10 100 1000Base T copper port PoE power supply Not supported Not supported Power consumption static 3 7 W 7 8 W Power consum...

Страница 15: ...e GB4943 1 Appendix B LEDs LED Status Description Power LED power Steady green The switch is powered on and the power module is operating correctly Off The switch is not powered on or the power module...

Страница 16: ...ng green The port is receiving or sending data at 1000 Mbps Steady yellow A 10 100 Mbps link is present Flashing yellow The port is receiving or sending data at 10 100 Mbps Off No link is present PoE...

Страница 17: ...17 2017 New H3C Technologies Co Ltd Website http www h3c com hk E mail service h3c com...

Отзывы: