![H3C F5000-AI160 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/h3c/f5000-ai160/f5000-ai160_manual_3116420007.webp)
5
•
If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE)
to filter interference from the power grid.
•
Keep the firewall far away from radio transmitting stations, radar stations, and high-frequency
devices.
•
Use electromagnetic shielding, for example, shielded interface cables, when necessary.
•
To prevent signal ports from getting damaged by overvoltage or overcurrent caused by lightning
strikes, route interface cables only indoors. If part of the network cable of an Ethernet port must
be routed outdoors, connect a lightning arrester to the cable before you plug the cable into the
port.
Lightning protection
To protect the firewall from lightning better, follow these guidelines:
•
Make sure the grounding cable of the chassis is reliably grounded.
•
Make sure the grounding terminal of the AC power receptacle is reliably grounded.
•
Install a lightning arrester at the input end of the power supply to enhance the lightning
protection capability of the power supply.
IMPORTANT:
No network port lightning arrester or AC power lightning arrester is provided with the firewall.
Prepare them as required. For the technical specifications and installation instructions for the
lightning protectors, see the documents shipped with them.
Power supply
Verify that the power system at the installation site meets the requirements of the power supplies,
including the input method and rated input voltage. For more information, see "Appendix A Chassis
views and technical specifications."
Installation tools
All installation tools are user supplied.
Table1-4 Installation tools
Flat-head screwdriver
Phillips screwdriver
Needle-nose pliers
Marker
Diagonal pliers
ESD wrist strap